Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Conrad BAR 899 HG Bedienungsanleitung

3-kanalfunk-wetterstation
Inhaltsverzeichnis

Werbung

10. Ranges and radio interference ........................................................... 72
11. Handling................................................................................................ 73
12. Maintenance and cleaning .................................................................. 73
13. Disposal ................................................................................................ 74
a) General information............................................................................ 74
b) Battery/rechargeable battery disposal................................................ 74
14. Technical specifications ..................................................................... 75
a) Base unit ............................................................................................ 75
b) Remote sensor ................................................................................... 75
15. Declaration of conformity (DOC) ........................................................ 76
42

14. Technical data

a) Base unit
Temperature measuring range: .. -5.0 °C to +50.0 °C (23.0 °F to 122.0 °F)
Resolution:.............................. 0.1 °C (0.2 °F)
Humidity measuring range: ......... 25 % to 95 % rel. humidity (at 25 °C / 77 °F)
Resolution:.............................. 1 %
Barometric pressure
measuring range:.................... 795 to 1050 mb/hPa (23.48 to 31.01 inHg)
Number of remote sensors: ........ maximum 3
Temperature sensing cycle: ....... approx. 30 seconds
DCF reception:............................ DCF77 from Frankfurt on the Main
Power supply: ............................. 4 x Mignon (AA), alkaline batteries are
recommended
Weight:........................................ approx. 256 g (without batteries)
Dimensions: ................................ 189 mm x 103 mm x 70 mm (H x W x D)
b) Remote sensor
Temperature measurement:
Measuring range:.................... -20.0 °C to +60.0 °C (-4.0 °F to 140.0 °F)
Resolution:.............................. 0.1° C (0.2 °F)
Humidity measurement:
Measuring range:.................... 25 % to 95 % rel. humidity (at 25 °C / 77 °F)
Resolution:.............................. 1 %
Radio transmission frequency:.... 433 MHz
Radio transmission range: .......... maximum 30 meters
Temperature sensing cycle:........ approx. 40 seconds
Power supply: ............................. 2 x Micro (AAA), alkaline batteries are
recommended
Weight:........................................ approx. 58 g (without batteries)
Dimensions: ................................ 92 mm x 60 mm x 20 mm (H x W x D)