7.1 Routine Maintenance
Follow the instructions in the "Switching off " section and abide by the recommendations in the table
below.
INTERVAL FOR MAINTENANCE
Each time used
Weekly
Monthly
CAUTION
• During use, the high pressure cleaner should not be too noisy and large amounts of water or oil should
not drip from underneath it.
In this event, a Skilled Technician should test the appliance.
7.2 Special Maintenance
WARNING
• Only Skilled Technicians are authorised to carry out special maintenance.
Follow the instructions in the table below for special maintenance.
INTERVAL FOR MAINTENANCE
Every 100 hours
Every 200 hours
CAUTION
• The data in the table are indications.
8 Dismantling And Disposal
Only trained personnel are allowed to dismantle the high pressure cleaner in accordance with the current
regulations in the country where it is installed.
In particular, the symbol
of together with normal household waste.
For further information, contact your local authority's waste disposal service or your local retailer.
WARNING
• Before disposing of the high pressure cleaner, make sure it is no longer possible to operate it, by cutting the
power supply cable for example. Make sure all its parts are inoffensive, as they could prove to dangerous
to children playing.
ACTION
• Check the supply cable, high-pressure pipe, couplings, cleaner gun, lance pipe.
Should any of these parts appear to be damaged, do not use the high
pressure cleaner and contact a Skilled Technician.
• Clean the water inlet filter (15).
Usually, it is sufficient to pass the filter under running water or in a jet of
compressed air to clean it. In more difficult cases, use a lime scale remover or
replace the filter. Contact an authorised service centre for the purchase of a
new filter.
• Clean the nozzle.
For cleaning, it is generally enough to pass the supplied pin (17) inside the
nozzle hole. In case you do not obtain any appreciable result, replace the nozzle
by using the supplied wrench (16). For purchasing the spare part, apply to an
authorised service centre.
ACTION
Check the pump hydraulic circuit.
Check the pump fixing.
Replace the pump oil.
Check the pump suction/delivery valves.
Check the pump screws are tightened.
Check the pump adjustment valve.
Check the safety devices.
on the identification plate (18) indicates the product must not be disposed