The sauna does not heat up.
The sauna is too big in relation to the stove's heating capacity ( › Technical Data).
There is lots of non-insulated wall surface in the sauna ( › General).
The burning material is moist or its quality is otherwise low ( › Burning Material).
The flue does not have a good draught.
The smoke canals of the stove are blocked ( › Maintenance).
The stove stones do not heat up.
The sauna is too small in relation to the stove's heating capacity ( › General).
The flue does not have a good draught.
The burning material is moist or its quality is otherwise low ( › Burning Material).
The smoke canals of the stove are blocked ( › Maintenance).
Check the stone placement ( › Sauna Stones). Remove the small pieces of stone and stones that are less than 10
cm in diameter from the stone space. Replace the disintegrated stones with large and undamaged ones.
The stove emits smell.
See section › Preparing the Stove for Use
The hot stove may emphasize odours mixed in the air that are not, however, caused by the sauna or the stove.
EN
Examples: paint, glue, oil, seasoning.
Wooden surfaces of the sauna room blacken
It is perfectly normal for the wooden surfaces of the sauna room to blacken in time. The blackening may be
accelerated by sunlight, heat from the stove, protective agents on the walls (protective agents have a poor heat
resistance level), fine particles disintegrating from the sauna stones which rise with the air flow and smoke that
enters the sauna, for example, when adding firewood.