3.
Wait a minute.
4.
Set the 400 V circuit breaker (8) or the 230 V circuit
breaker (8a) to "ON".
Attention! Defective circuit breakers may only be re-
placed with identical circuit breakers with the same
power data. Contact customer service for this.
10.6 "RESET" button (12) for 12 V (Fig. 1)
If the overload protection has been triggered, the
"RESET" button (12) restores the output power of the
power generator. It is then not necessary to restart the
engine.
1.
Wait a minute.
2.
Press the "RESET" button (12).
10.7
Charging external devices (Fig. 1, 3)
m DANGER!
Danger due to incorrect charging.
1.
Plug the adapter cable with 12 V terminals (C) in-
to the 12 V DC connection (13) provided for this.

12. Maintenance

WARNING!
Always wear protective gloves and a mask during maintenance work!
12.1
Maintenance plan
Always comply with the following maintenance intervals in order to ensure problem-free operation.
ATTENTION! At initial start-up, engine oil and fuel must be filled.
Checking the engine oil
Changing the engine oil
Checking the air filter
Cleaning the air filter
Visual inspection of the device
Cleaning the spark plug
Check and readjust the throttle
valve
Cleaning the cylinder head
Adjust the valve play
Attention: Only have points "X*" carried out by an authorised specialist company.
36 | GB
Before every
after operating for
use
20 hours
X
X
X
first time, then
every 50 hours
www.scheppach.com

11. Cleaning

Before carrying out any cleaning or maintenance work,
switch off the engine and remove the ignition key (14)
from the ignition lock (14a). In addition, remove the
spark plug connector (20) from the spark plug (20a).
ATTENTION! Danger of burning! Wait until the de-
vice has cooled down before performing cleaning or
maintenance work.
11.1
Cleaning
Keep protective devices, air vents and the engine
housing as free of dust and dirt as possible. Rub the
device clean with a clean cloth or blow it off with com-
pressed air at low pressure. We recommend that you
clean the device directly after every use.
Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic parts
of the device. Make sure that no water can penetrate
the device interior.
after operating for
50 hours
X
X
Gap: 0.7 - 0.8 mm,
replace if necessary
after operating for
300 hours
Change filter in-
sert if necessary
X*
X*
X*