Releasing pressure
If the tyre pressure is too high, press the air release button
(14.7). Hereby, compressed air will be released. Lower the tyre
pressure to the desired value.
11.3 Adapter set (15)
With the adapter set (15) you can inflate e.g. balls, air mat-
tresses or bicycle tyres.
11.3.1 Usage
• Select the right adapter for your application from the adapt-
er set (15).
• Attach the selected adapter to the valve plug connection
(14.2) of the compressed air tyre inflation meter (14). To do
this, press the lever on the valve plug connection (14.2) to
unlock the clamping mechanism.
• As soon as you release the lever, the valve plug connection
(14.2) clamps on the adapter.
• Press the lever of the valve plug connection (14.2) again to
release the valve plug connection from the valve.

12. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomer's mains connection as well as the extension
cable used must also comply with these regula-
tions.
When working with spray attachments and during temporary
use outdoors, the device must be connected to a residual cur-
rent circuit breaker with a trigger current of 30 mA or less.
Damaged electrical connection cable
The insulation on electrical connection cables is often dam-
aged.
This may have the following causes:
• Pressure points, where connection cables are passed through
windows or doors.
• Kinks where the connection cable has been improperly fas-
tened or routed.
• Places where the connection cables have been cut due to
being driven over.
• Insulation damage due to being ripped out of the wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be used
and are life-threatening due to the insulation damage.
Check the electrical connection cables for damage regularly.
Ensure that the connection cables are disconnected from elec-
trical power when checking for damage. Electrical connection
cables must comply with the applicable VDE and DIN provisions.
Only use connection cables with the designation H05VV-F.
The printing of the type designation on the connection cable
is mandatory.
Safety instructions for the replacement of dam-
aged or defective power supply cables
22
GB
Type X:
If the power cord of this device is damaged, it must be replaced
by the manufacturer, their service department or a similarly
qualified person to avoid dangers.
AC motor
• The mains voltage must be 230 V ~ .
• Extension cables up to 25 m long must have a cross-section
of 1.5 mm
.
2
Connections and repair work on the electrical equipment may
only be carried out by electricians.
Please provide the following information in the
event of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Engine data - type plate
13. Cleaning, maintenance, storage and
ordering spare parts
m Attention!
Pull out the mains plug before carrying out any cleaning or
maintenance work! Danger of injury due to electric shocks!
m Attention!
Wait until the device has cooled down completely! Danger of
burning!
m Attention!
Depressurise the device before carrying out any cleaning or
maintenance work! Danger of injury!
13.1 Cleaning
• Keep the device as free of dust and dirt as possible. Rub
the device clean with a clean cloth or blow it off with com-
pressed air at low pressure.
• We recommend that you clean the device directly after every
use.
• Clean the device at regular intervals using a damp cloth and
a little soft soap. Do not use any cleaning products or sol-
vents; they could attack the plastic parts of the device. Make
sure that no water can penetrate the device interior.
• The hose and injection tools must be disconnected from the
compressor before cleaning. The compressor must not be
cleaned with water, solvents or similar.
13.2 Maintenance of the pressure vessel (Fig. 3)
m Attention!
To ensure a long service life for the pressure vessel (3), drain off
the condensate after each use by opening the drain screw (5).
Release the boiler pressure beforehand (see 13.4.1).
The drain screw (5) is opened by turning it anti-clockwise
(when looking at the screw on the bottom of the compressor)
so that the condensate can be completely drained out of the
pressure vessel (3).
In order to drain the condensation water completely out of the
pressure vessel (3), it must be tilted slightly to the side so that
the drain screw (5) is the lowest point.