Herunterladen Inhalt Inhalt Diese Seite drucken

Faults - Kärcher HD 801 B Cage Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für HD 801 B Cage:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Flush device with anti-freeze agent
Note
Observe handling instructions of the anti-
freeze agent manufacturer.
 Pump in conventional frost protection
agents through the appliance.
A certain corrosion protection is achieved
with this as well.

Faults

Danger
Risk of injury if the machine is left running
in an unattended state. Remove the spark
plug before doing any work on the appli-
ance.
Risk of burns! Do not touch hot silencers,
cylinders or radiator ribs.
Appliance is not running
Follow operating instructions of the engine
manufacturer!
With HD 801 Cage only:
Safety thermostat at the high pressure
pump has switched off the appliance af-
ter long period of cycle operation.
 Allow the appliance to cool down; then
restart it. Refer section "Interrupting op-
eration".
Device is not building up pressure
Operating speed of the engine is too low
 Check operating speed of the engine
(refer to technical data).
Nozzle is set to "CHEM"
 Set nozzle to "High pressure".
Nozzle is blocked/ washed out
 Clean/ replace nozzle.
Sieve in the water connection is dirty
 Clean sieve.
Air within the system
 Appliance ventilation:
Amount of water supply is too low.
 Check water supply level (refer to tech-
nical data).
Pipe inlets to pump are leaky or blocked
 Check all inlet pipes to the pump.
Device leaks, water drips from the
bottom of the device
Pump leaky
Note
3 drops/minute are allowed.
 With stronger leak, have device
checked by customer service.
Pump is vibrating
Inlet pipes to the pump are leaky.
 Check all inlet pipes to the pump.
Air within the system
 Appliance ventilation:
Detergent is not getting sucked in
Nozzle is set to "High pressure"
 Set nozzle to "CHEM".
Detergent suction hose with filter is
leaky or blocked
 Check/ clean detergent suction hose
with filter.
Backflow valve in the connection of the
detergent suction hose is jammed
 Clean/ replace backflow valve in the
connection of the detergent suction
hose.
HD 1050 B, HD 1050 DE only:
Detergent dosing valve is closed or
leaky/ blocked
 Open or check/clean detergent dosing
valve.
If malfunction can not be fixed, the de-
vice must be checked by customer ser-
vice.
– 8
EN
23

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hd 1050 b cageHd 1050 de cage

Inhaltsverzeichnis