Charging has been suspended:
1) if the ambient temperature is below -20°C/-4°F or above 55°C / 131°F, indicated by the selected mode LED
(Pb / LFP) blinking together with LED #8.
Corrective action: When the temperature is back within range the selected mode LED will stop blinking and
turn full on. Press and release the pushbutton to cancel the error (LED #8) for charging to continue.
2) during SAVE mode or the Voltage Retention Test. The battery may have suffered fatal damage and may be
unserviceable.
Corrective action: Thoroughly inspect the battery; refer to Section A. Preparing to charge, Very flat
neglected batteries. If damage is suspected, disconnect the battery and do not charge further. Otherwise,
press and release the pushbutton to cancel the error (LED #8) for charging to continue. IMPORTANT: If the
Error repeats, DO NOT CHARGE AGAIN!
LED #6 or #6/7 - FINAL CHARGE
STEP 10 - The ampmatic™ current control program now delivers pulses of current up to a voltage of
14.4V, to equalise the individual cells within the battery and optimizes charge level. Charge time is 2h / 120
minutes.
STEP 11 - the MAINTENANCE CHARGE CYCLE consists of 30 minute charge periods followed by and alternating
with a 30 minute 'rest' periods, during which there is no charge current. During the 30 minute charge cycles
current is delivered only if the battery has lost charge as compared to the TEST result in STEP 9.
60' mode: For a healthy battery the program progresses from STEP 9 directly to STEP 11.