TROUBLESHOOTING
5.3

ELECTRICAL CIRCUITS ____________________________________________________

When troubleshooting the machine using the controller,
always check that Program Active lamps (2 and 3) are on.
These indicate that the controller has power and the
program is active.
NOTICE
The controller requires a minimum of six volts to operate.
Individual circuits can be tested by operating an input
switch, checking for the required input signal, and looking for
a corresponding output. Keep in mind that not all switches
are located on the instrument panel. The traction pedal, reel
lift limit, and brakes are controlled by small reed switches
mounted on the frame of the mower.
If an input lamp does not light an inactive condition is
indicated. This could be caused by a fuse, faulty switch, or
poor connection.
The electrical connections to the solenoids on the hydraulic
valves are also equipped with small indicator lamps. When
lit these lamps indicate that the output signal has reached
the connection. If lamps do not come on, check wires to and
from connector.