5. Settings

Various settings can be made depending on the selection of hydraulic
variant (see "7.1. Program selection" on page 26).
Caution

5.1. Solar

5.1.1. Tmin S1

Enable/start temperature at sensor 1
If this value is exceeded at sensor 1 and the other conditions are also met, the
controller switches the associated pump and/or ball valve on. If the tempera-
ture at sensor 1 drops below this value by 5 °C, the pump and/or the valve are
switched off again.
Setting range: 0 °C - 99 °C/Default: 20 °C

5.1.2. Tmax S2

Switch-off temperature at sensor 2
If this value is exceeded at sensor 2, the controller switches the associated
pump and/or valve off. If sensor 2 falls below this value again and the other con-
ditions are also met, the controller switches the pump and/or ball valve on again.
Setting range: 0 °C - 99 °C/Default: 30 °C
Settings
Temperature values which are set too high can lead to scalding or
damage to the system. Scalding protection must be provided by
the customer!
The necessary basic settings required for the
control function are made in the menu "5. Set-
tings".
This does not under any cir-
cumstances replace the safety
facilities to be provided by the
Caution
customer!
The menu is closed by pressing the "esc" key
or selecting "Exit settings".