INDOOR UNIT INSTALLATION

Step 1: Select Installation location
1) Ensure the installation complies with the installation
minimum dimensions (defined below) and meets the
minimum and maximum connecting piping length and
maximum change in elevation as defined in the System
Requirements section.
2) Air inlet and outlet will be clear of obstructions,
ensuring proper airflow throughout the room.
3) Condensate can be easily and safely drained.
4) All connections can be easily made to outdoor unit.
5) Indoor unit is out of reach of children.
6) A mounting wall strong enough to withstand four
times the full weight and vibration of the unit.
> 13cm / 5 in.
Step 2: Install Mounting Plate
1) Take the mounting plate from the back of indoor unit.
2) Ensure to meet the minimum installation dimension
requirements as step 1, according to the size of
mounting plate, determine the position and stick the
mounting plate close to the wall.
3) Adjust the mounting plate to a horizontal state with
Note: (I) Make sure the mounting plate is firm enough
and flat against the wall after installation.
20 ACD-24KBTU
7) Filter can be easily accessed for cleaning.
8) Leave enough free space to allow access for routine
maintenance.
9) Install at least 10 ft. (3 m) away from the antenna of
TV set or radio. Operation of the air conditioner may
interfere with radio or TV reception in areas where
reception is weak. An amplifier may be required for the
affected device.
10)
Do not install in a laundry room or by a
swimming pool due to the corrosive environment.
11) For ETL certification area, Caution: Mount with the
lowest moving parts at least 8 ft. (2.4 m) above floor or
grade level.
Ceiling
> 20cm / 8 in.
> 250cm / 8ft.
Floor
a spirit level, then mark out the screw hole positions on
the wall.
4) Put down the mounting plate and drill holes in the
marked positions with drill.
5) Insert expansion rubber plugs into the holes, then
hang the mounting plate and fix it with screws.
Spirit leve
l
Mounting plate
(II)This figure shown may be different from the actual
object, please take the latter as the standard.
> 13cm / 5 in.
Reference screw positions