Installation

Installation

Important Information

!
• This appliance is NOT intended for use in a commercial
environment.
• The appliance is fitted with a plug and must only be
connected to a properly installed earthed socket.
• In case a new socket is needed, installation and cable
connection must only be done by a qualified electrician.
If the plug is no longer accessible following installation,
a pole disconnecting device must be present on the
installation site with a contact gap of at least 3 mm.

Notes on the installation of the appliance

• This appliance is only intended to be fully fitted in a
kitchen.
• This appliance is not designed to be used as a tabletop
appliance or inside a cupboard.
• The fitted cabinet must not have a back wall behind the
appliance.
• A gap of at least 45mm must be maintained between
the wall and the base or back panel of the unit above.
• The fitted cabinet must have a ventilation opening of

Installation dimensions

Ventilation openings
on the back
min. 250 cm
600
min.
560
550
No rear panel
behind the
appliance
Ventilation slot
under the lowest
cabinet shelf
min. 250 cm
2
Note: According to the dimensions given, there should be a gap above the appliance.
60
2
+8
min. 45
min.
550
50
460
+2
450
+2
Ventilation slot
under the lowest
cabinet shelf
min. 250 cm
2
• Adapters, multiway strips and extension cords must not
be used. Overloading can result in fire.
• If the appliance is not fitted with a supply cord and a
plug, the connection equipment must have a contact
separation in all poles that provide full disconnection,
and the appliance must be incorporated in the fixed
wiring in accordance with the wiring rules.
250 cm² on the front. To achieve this, cut back the base
panel or fit a ventilation grille.
• Ventilation slots and intakes must not be covered.
• The safe operation of this appliance can only be gua-
ranteed if it has been installed in accordance with these
installation instructions.
• The fitter is liable for any damage resulting from incor-
rect installation.
• The unit into which the appliance is fitted must be heat-
resistant up to 90°C.
560
+8
No rear panel
behind the
appliance
Ventilation grid
min. 45
Furniture feet