1.
No modifications are allowed to be made to the
generator
2.
The speed preset by the manufacturer may not
be changed. The generator or connected devices
could be damaged.
Risk of poisoning! Fumes, fuels and lubricants
3.
are toxic. Do not breath in the fumes.
Fire risk! Petrol and petrol fumes are highly flam-
4.
mable and explosive.
5.
Motor exhaust gases are toxic. The generator
must not be operated in unventilated rooms. If
the generator is to be operated in well-ventilated
rooms, the exhaust gases must be discharged di-
rectly outside via an exhaust gas hose. Additional
requirements for protection against fire and ex-
plosion must also be observed. Even when using
an exhaust hose, toxic gas can still escape. Due
to the risk of fire, the exhaust hose should never
be aimed at combustible material.
6.
Never use the generator in rooms with highly
flammable materials.
Hot surface! Risk of burning, do not touch the
7.
exhaust system and engine unit.
8.
Do not touch any of the mechanically moving or
hot parts. Do not remove any of the protective
caps.
Protective equipment! Use suitable ear protec-
9.
tion when near the device.
10. Only original parts should be used for mainte-
nance and accessories.
11. Repair and maintenance work must only be per-
formed by authorised qualified personnel.
12. Protect yourself from electric shocks.
13. Never touch the generator with wet hands
14. Only use outside with a extension cable which
is suitable for that and is appropriately marked
(H07RN).
15. If extension cables or mobile distribution net-
works are used, the resistance value must not
exceed 1.5 Ω. When using extension cables, the
total length of cables for a cross section of 1.5
mm
should not exceed 60 m; for a cross section
2
of 2.5 mm
, 100 m should not be exceeded.
2
16. Do not use the generator in the rain or snow.
17. Always turn off the engine when transporting or
refuelling.
18. Fuel is combustible and highly flammable. Do
fuel the unit during operation. Do not fuel the unit
when someone is smoking or near open flames.
Do not spill any fuel.
19. Do not refuel or empty near naked lights or flames
or flying sparks. Do not smoke!
20. Put the generator on a secure and level place.
Turning, tipping or changing its position during
operation is forbidden.
21. Install the generator at least 1 m away from the
walls or attached devices.
20 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
22. Children must be protected by ensuring that they
stay a safe distance away from the generator.
23. Some parts of the reciprocating internal combus-
tion motor are hot and may cause burns. The
warnings on the generator must be observed.
24. Emission levels are represented in the technical
data under the stated values for sound power
level (L
) and sound pressure level (L
WA
are not compulsory definite working levels. Be-
cause there is a connection between emission
levels and immission levels, this can not reliably
used to determine the potentially necessary ad-
ditional precautions. Influencing factors on the
workforce's current immission level includes the
properties of the work area, other noise sources,
air borne sound, etc. such as e.g. the number of
machines and other neighbouring processes and
intervals, to which the user is exposed. Also the
admissible immission levels can vary from coun-
try to country. However, this information gives the
user of the machine the opportunity to have a
better estimation of the risks and dangers. Occa-
sionally acoustic measurements should be take
after installation in order to determine the sound
pressure level.
25. Warning! Follow the electrical safety regulations
that apply to the location where the generators
are used.
26. Warning! Take into account the requirements and
precautionary measures in the event of genera-
tors being re-supplied, depending on the protec-
tive measures of this device and the applicable
directives.
27. Generator sets should only be used up to their
rated output under the rated ambient conditions.
If the application of the generating set is carried
out under conditions which do not comply with the
reference conditions of ISO 8528-5 (7.1), and if
the cooling of the motor or generator is impaired,
e.g. as a result of operating in restricted areas, a
reduction in performance is required.
28. Do not cover the generator or place any objects
on top of the generator.
ATTENTION: Only use unleaded normal petrol as
fuel.
Warning! This electric tool generates an electro-
magnetic field during operation. This field can impair
active or passive medical implants under certain
conditions. In order to prevent the risk of serious or
deadly injuries, we recommend that persons with
medical implants consult with their physician and the
manufacturer of the medical implant prior to operat-
ing the electric tool.
) and
pA