Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch MS 100 Installationsanleitung Seite 31

Vorschau ausblenden Andere Handbücher für MS 100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
VS1,
PS2, PS3
N 74 75
N L
M
PS5*
Legend to above Fig. and Fig. 17 to 23, from page 199:
Solar thermal system
Function
Additional function (shown in grey)
Freshwater system
Function
Additional function (shown in grey)
Earth lead
Temperature/temperature sensor
BUS connection between heat source and module
No BUS connection between heat source and
module
Terminal designations:
230 V AC Mains voltage connection
BUS
BUS system connection
OS1
Connection for pump speed modulation (PWM or
0-10 V) (Output Solar) / Terminal assignment:
1 – earth; 2 – PWM/0-10 V output; 3 – PWM input
(optional)
PS1...3
Pump connection (Pump Solar)
TS1...3
Temperature sensor connection (Temperature
sensor Solar)
VS1
3-way valve connection or 3-way mixing valve
(Valve Solar)
IS1
Connection for heat meter (Input Solar)
Terminal assignment: 1 – earth (water meter and
temperature sensor); 2 – flow rate (water meter);
3 – temperature (temperature sensor); 4 – 5 V DC
(power supply for vortex sensors)
MS 100
MS 100
120/230 V AC
VS1, PS2, PS3
120/230VAC 120/230VAC
N L
N
L
N 74
N L
M
230 VAC
230 VAC
PS6*
PS9*
≤ 24 V
IS1
1
2
3
≤ 24 V
PS1
TS1 TS2
75
N 63
1 2 1 2
N L
M
PS1
TS1 TS2
Solar system components:
230 V AC Mains voltage
BUS
EMS 2/EMS plus BUS system
PS1
Solar circuit pump for collector array 1
PS5
Cylinder primary pump when using an external heat
exchanger
PS6
Cylinder transfer pump for transfer system without
heat exchanger (and thermal disinfection)
PS9
Thermal disinfection pump
PS11
Pump on the heat source side (primary side)
PS13
DHW circulation pump
MS 100 Module for standard solar thermal systems
TS1
Temperature sensor for collector array 1
TS2
Cylinder 1 bottom temperature sensor
TS6
Heat exchanger temperature sensor
TS9
Cylinder 3 top temperature sensor, connection e.g.
to heat appliance (do not connect to MS 100)
TS12
Temperature sensor in flow to solar collector
(heat meter)
TS13
Temperature sensor in return from solar collector
(heat meter) 7
TS17
Temperature sensor on the DHW heat exchanger
(secondary side)
TS21
Temperature sensor at heat exchanger
(flow, primary side)
VS5
3-way valve in return
VS6
Valve for cascade
WM1
Water meter
OS1
4 1
2 3
TS3
BUS
1 2
1 2
V
TS6*
WM1
TS13
BUS
TS12*
6 720 810 985-01.1O
6 720 815 256 (2014/10)
Installation | 31
1 2 3
PWM
0-10V
PS1

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis