Figure 9
Warning!! Only lower each column
alternately by a max. of 5-10 cm
otherwise there is a danger of fall-
ing.
The entire emergency discharge must always be ob-
i
served by the operator.
i
The lift must be stopped until the defective parts are
exchanged.
The lift may only be operated
again once it has been returned to
a seamless condition seen from a
safety point of view.
• Afterwards, do a reset as described in the operating
manual.
6.3 Reset after an emergency discharge
i
A reset may only be done once the lift is in its lowest
position.
Access to the DIP switch may only
be done by a trained, authorised
specialist.
a) There may not be any vehicles on the lift.
b) Remove the rear column covers on the operating col-
umn.
c) Loosen and remove the electrical box cover.
Zeroing PIC
Manual:
A jumpered bridge over the push pin X501 Pin 1 and
2 while turning on the supply voltage and removing this
bridge within the first 2 seconds after turning on the volt-
age carries out a ZE-ROING of the counter status.
The LED K500 must light up.
Only stick the push pin (jumper) for saving on one pin
(v bridge open)
OPI_POWER LIFT HDL 6500 SST DG-7000 SST DG-8000 SST DG_V4.0_DE-EN-FR-ES-IT
Figure 4a (Pos. 26): Jumpered bridge
Figure 4b (Pos. 26): One pin (bridge open)
d) The lift must be raised and lowered several times with-
out a vehicle while observing the entire lifting and low-
ering process.
e) The covers must be replaced.
7
Maintenance and care
i
Before maintenance, do all preparation work so there
is no danger to life or limb or object damage during
maintenance and repair work.
Legal principles: BSV (operating equipment regula-
i
tion) + BGR500 (Operation of work equipment)
To guarantee the largest possible availability and func-
tional capacity of the system, ensure the list of any clean-
ing, care and maintenance work is done.
The system is to be serviced at regular intervals according
to the following plan. For intensive operation and higher
degree of contamination shorten the service interval.
The complete function of the system is to be observed
during daily use. Customer service must be informed of
any malfunctions or leaks.
119