Compressed air maintenance unit
Setting the working pressure
Check the working pressure displayed in the
pressure gauge
. This must correspond to the
technical data.
The working pressure can be adjusted by means of
the pressure regulator
Pull the pressure regulator up to make adjustments.
To increase the pressure in the machine, turn the
regulator clockwise. To decrease the pressure, turn
the regulator counterclockwise.
Oiler
Check the oil level in the oil reservoir
Remove the oil reservoir.
Now refill the reservoir with a pneumatic oil of
SAE20 viscosity accordingly.
Check the injection quantity of the oiler through the
sight glass
.
As a rule, the screw
in a clockwise direction and then opened
again by approx. 1/4 to 1/2 turn by turning it
counterclockwise.
Water separator
Check the water level in the separator
Open the valve
to drain the water.
4.6

Disposal

Disconnect the air and power supply.
Remove all non-metallic materials and store them according to local regulations.
Remove the oil from the machine and store it according to local regulations.
Recycle all metallic materials.
Danger
The machine contains some hazardous substances.
These can pollute the environment and cause damage to the human body.
Pay attention to appropriate caution and, if necessary, protective clothing when handling.