Herunterladen Inhalt Inhalt Diese Seite drucken

Inspection And Maintenance; Spare Parts - Gemü 695 Betriebsanleitung

Pneumatisch betätigtes membranventil
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

16 Inspection and maintenance

16 Inspection and maintenance
The equipment is subject to pressure!
▶ Risk of severe injury or death
Depressurize the plant.
Completely drain the plant.
Hot plant components!
▶ Risk of burns
Only work on plant that has cooled
down.
Servicing and maintenance work must only be performed
by trained personnel.
Do not extend hand lever. GEMÜ shall assume no liability
whatsoever for damages caused by improper handling or
third-party actions.
In case of doubt, contact GEMÜ prior to commissioning.
▶ The valve with a stainless steel body has CIP/SIP clean-
ing and sterilizing capabilities.
The operator must carry out regular visual examination of the
GEMÜ products dependent on the operating conditions and
the potential danger in order to prevent leakage and damage.
The product also must be disassembled and checked for
wear in the corresponding intervals.
1. Have servicing and maintenance work performed by
trained personnel.
2. Wear appropriate protective gear as specified in plant op-
erator's guidelines.
3. Shut off plant or plant component.
4. Secure the plant or plant component against recommis-
sioning.
5. Depressurize the plant or plant component.
6. Actuate GEMÜ products which are always in the same po-
sition four times a year.
GEMÜ 695
WARNING
CAUTION
CAUTION
NOTICE

16.1 Spare parts

Vent hole
Actuator
membrane
Connector 2
19
18
Item
A
Actuator
1
Body
2
Diaphragm
18, 19, 20
Screw connection kit
70 / 80
Optical position indicator
Leak detection
Name
Order designation
9695
K600
Code 2
Code 4
Code 13
Code 17
Code 19
Code 28
Code 29
Code 36
695 S30
www.gemu-group.com
A
hole
2
1

Werbung

Inhaltsverzeichnis
loading