Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Data - JUMO di 32 Betriebsanleitung

Digitale anzeigeinstrumente
Vorschau ausblenden Andere Handbücher für di 32:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electrical data

Supply
(switch-mode power supply)
Test voltages (type test)
Power drawn
Data backup
Electrical connection
Electromagnetic compatibility
Safety regulation
Case
Case type
storage temperature range
Operating position
Protection
Weight
10 — 18V DC ±0% or
110 — 240V AC -15/+10% 48 — 63Hz, or
20 — 53V AC/DC 48 — 63Hz
to EN 61 010, Part 1, March 1994,
overvoltage category II, pollution degree 2, for Type 951530/...
overvoltage category III, pollution degree 2, for Type 951531/...
at the rear via plug-in screw terminals,
conductor cross-section ≤ 1.5mm
2
2
2x 1.5mm
(1.0mm
for Type 951530/...), with core end sleeves
EN 61 326, NAMUR recommendation NE21 (as per May 1993)
plastic case for panel mounting to DIN 43 700
to EN 60 529, front IP66, rear IP20
75g approx.
5VA max.
EEPROM
2
2
(1.0mm
for Type 951530/...) or
to EN 61 010-1
-40 to +70°C
any
160g approx.
31