Input for resistance thermometer
Designation
Pt100
EN 60 751
Pt100
EN 60 751
Pt1000
EN 60 751
Pt1000
EN 60 751
KTY11-6
Sensor lead resistance
Measuring current
Lead compensation
Decimal place
= factory setting
Connection circuit
2-wire
3-wire
2-wire
3-wire
2-wire
20 Ω max. per lead in 2-wire and 3-wire circuit
not required for 3-wire circuit. For 2-wire circuit, lead compensation can be
implemented in software through actual-value correction.
Range
Measurement
accuracy
≤ 0.1%
-200 to +850°C
≤ 0.1%
-200 to +850°C
≤ 0.1%
-200 to +850°C
≤ 0.1%
-200 to +850°C
≤ 1.0%
-50 to +150°C
250µA
configurable
Ambient
temperature
error
50 ppm/°C
50 ppm/°C
50 ppm/°C
50 ppm/°C
50 ppm/°C