RCD10.5
Code
Audio alarm
W02
E03
W04
W10
W11
W19
E32
E33
E34
E35
RCD10.5ES, RCD10.5XES
In the event of a fault, the warning LED (
All faults of the WARNING (W) type are reset automatically once the fault has been
rectified.
All faults of the ERROR (E) type must be reset manually:
➤ Press
for 2 seconds.
✔ A beep sounds.
✔ The error has been reset.
Number of
Audio alarm
flashes
Continuous
1
EN
Fault
No
Defective temperature sen-
sor in the refrigerator com-
partment
Yes
Communication error
No
CI bus fault
Yes
Door open for more than
2 minutes
Yes
DC voltage <7.5 V
Yes
DC voltage <10.9 V
Yes
Outer fan overcurrent
Yes
Compressor does not start
Yes
Compressor overload
Yes
Thermal cut out compressor
controller unit
Fault type Fault
No
W
Yes
W
Solution
➤ Contact an authorized cus-
tomer service point.
➤ Press the on/off button for at
least 2 seconds.
Resets automatically
➤ Close the door.
Resets automatically
Resets automatically
➤ Press the on/off button for at
least 2 seconds.
➤ Press the on/off button for at
least 2 seconds.
➤ Press the on/off button for at
least 2 seconds.
➤ Press the on/off button for at
least 2 seconds.
in the display flashes.
)
Defective temperature sen-
sor in the refrigerator com-
partment
DC voltage <10.9 V
Troubleshooting
Solution
➤ Contact an author-
ized customer ser-
vice point.
Resets automatically
25