Package Contents
(1) Celsus iVT foot
(1) Foot Shell
(1) CPI Sock
(1) iVT Tube Kit
This diagram (Figure 1) is to help familiarize you with the unique parts of the Celsus iVT. These parts are referenced in
the instructions and used when speaking with a technical service representative.
Key Components (Figure 1)
FOOT
A.
Integrated Pyramid
E.
Heel Spring
• CPI Sock (not shown)

PRODUCT DESCRIPTION

This prosthetic foot device is constructed with an integrated pyramid, mechanical vacuum pump, housing, two
composite springs, and heel wedge. The toe spring is secured to the housing and heel spring with fasteners.
INTENDED USE
The Celsus iVT is a prosthetic foot designed to replace one or more functions of the biologic human foot. The
device incorporates a vacuum pump to draw air from the socket for the purpose of suspension.
INDICATIONS:
▪ Lower limb amputations
PROTECTIVE COVER ON DOME
Remove the protective cover on dome after alignment is completed and before patient leaves clinic.
CELSUS IVT OVERVIEW
▪ During full dorsiflexion the maximum attainable vacuum ranges from 18-22inHg.
▪ Vacuum suspension is generated when the user applies a load to the toe. The integrated pump draws air from
the socket during each step until elevated vacuum is achieved inside the socket.
▪ The firmness category of the foot can affect the number of steps needed to reach maximum vacuum pressure.
▪ Liner selection is the sole responsibility of the provider. College Park recommends against the use of
Copolymer Gel liners with the Celsus iVT Foot.

TECHNICAL SPECIFICATIONS

FOOT SIZE
WEIGHT LIMIT
21-24 cm
220 lbs / 100 kg
25-26 cm
300 lbs / 136 kg
27-30 cm
*26cm foot w/shell
GAIT MATCHING
The gait match determines the firmness of the foot based on the user's specifications (foot size, patient weight,
and impact level).
Tools Required
(1) 4 mm Hex Key
Tools Recommended
(1) Foot Horn
B.
C.
Housing
F.
G.
iVT Check Valves
• Foot Shell (not shown)

CONTRAINDICATIONS:

▪ Make sure that the socket is well fitting before any use; Never
use a loose fitting or leaking socket with the Celsus iVT Foot.
BUILD HEIGHT
2.2 in / 5.7 cm
2.5 in / 6.4 cm
2.6 in / 6.6 cm
GUIDELINES
®
D.
Toe Spring
H.
iVT Hose Connector
FOOT WEIGHT*
661 g
Heel Wedge (permanent)
iVT Exhaust Vent
EN