Herunterladen Inhalt Inhalt Diese Seite drucken

Cameo S4 IP Bedienungsanleitung Seite 14

Vorschau ausblenden Andere Handbücher für S4 IP:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 46
1
POWER IN
IP65 power input socket with rubber sealing cap (compatible with TRUE1). Operating voltage
100–240 V AC/50–60 Hz. Connection via supplied power cable (when not in use, always close
with rubber sealing cap).
2
POWER OUT
IP65 power output socket with rubber sealing cap (compatible with TRUE1). Facilitates power
supply to other CAMEO spotlights. Ensure that the total current consumption of all connected
devices does not exceed the value specified on the device in amperes (A) (when not in use,
always close with the rubber sealing cap).
3
DMX IN
Male IP65 5-pin XLR socket for connecting a DMX control device (e.g. DMX console; when not in
use, always close with the rubber sealing cap).
4
DMX OUT
Female IP65 5-pin XLR socket for sending DMX control signal (when not in use, always close with
the rubber sealing cap).
5
DATA IN
RJ45 IP65 network connector for connection to an ArtNet or sACN network. When setting up the
network, use IP65 cables of category CAT-5e or better (always seal with the rubber sealing cap
when not in use).
6
DATA OUT
RJ45 network connection with protection class IP65 for forwarding the control signal. When
setting up the network, use IP65 cables of category CAT-5e or better (always seal with the rubber
sealing cap when not in use).
7
BATTERY IN
Male 4-pin XLR socket with IP65 protection rating for connecting external batteries (batteries
not included in delivery). A double V-mount adapter with connecting cable is optionally available
(article number CLSVMOUNTAP).