Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Disposal/Environmental Protection; Error Correction - Parkside PBS 350 B2 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für PBS 350 B2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB
IE
NI

Troubleshooting

The following table will assist you in troubleshooting:
Problem
Machine does not
start
Machine works with
interruptions
Poor sawing perfor-
mance
Saw blade quickly
becomes blunt
Belt stuck in work
piece

Disposal/environmental protection

The machine, accessories and packaging
must be properly recycled.
Electrical devices must not be dis-
posed of with domestic waste.
20
CY
Possible cause
No mains power supply
On/off switch (30) is
broken
Defective motor
Internal loose contact
ON/OFF switch (30) is
broken
Band saw blade blunt
Pressure of workpiece
against band saw blade
too high or too low.
Band saw blade unsuit-
able for the work piece
to be worked on
Too much pressure ap-
plied
Belt too loose

Error correction

Check the socket, mains connec-
tion cable, plug and fuse and
have them repaired by a qualifi ed
electrician if necessary.
Contact the service centre.
Contact the service centre.
Contact the service centre.
Contact the service centre.
see "Changing the band saw
blade"
Adjust pressure
Insert a suitable band saw blade
Reduce the pressure
see "Checking and adjusting the
tension of the band saw blade"
• Take the machine to a recycling plant.
The plastic and metal parts used on
your machine can be properly sorted
according to materials and grades and
effi ciently recycled. Please contact our
service centre for more information.
• We will dispose of defective devices you
ship to us free of charge.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis