Troubleshooting
PX455, channel status
LED
Status
On
green
On
yellow
Flashing
On
red
PX878
On
green
Flashing
yellow
On
red
Synchronization SYNC
IN socket LEDs :
IN
Off
green
Off
Off
Off
yellow
A3257−2.0 en/de/fr
Significance
no errors
No transducer connected or wire break
(calibration ongoing)
Firmware update ongoing
Parameter not OK, transducer error,
overloaded
Analog
Analog output configured
Firmware update ongoing
Analog output overloaded,
Signal invalid or no signal assigned
Significance
Slave
Master
Error
Remedy
Check the cable connection to the
master/slave
155
Remedy
Connect the
transducer
Check the : sen-
sor, sensor
leads, TEDS mo-
dule,
send in the card
if necessary
Remedy
Check the sen-
sor signal, check
the settings for
the analog out-
put channel