Herunterladen Inhalt Inhalt Diese Seite drucken

Before Using The Device; Fit Welding Mask; Using The Device - Parkside PISG 100 A1 Bedienungs- Und Sicherheitshinweise

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

if possible, devices and systems at risk from interference radiation
should be removed from the work area or shielded.
Note!
This device complies with IEC 61000-3-12, provided that the Ssc
short circuit power is larger or equal to 3553.5 kW at the interface
point between the operator's supply and the public supply. It is the
responsibility of the installer or user of the device, after consultation
with the distribution system operator if necessary, to make sure that
the device is only connected to a supply with an Ssc short circuit
power which is larger or equal to 3553.5 W.
Note!
The device is only for use in areas which are supplied with a current
load capacity of at least 100 A per phase.
 Before using the device
Take the device and accessories out of the packaging and check them for damage
(e.g. transport damage).
Fix the carrying strap
 Fit welding mask
Fit the handle
onto the welding mask
8
Fit the protective glass
The protective glass
NOTE: If you are not able to push the protective glass
protective glass
.
11
 Using the device
NOTE: The welder is designed for welding with electrodes.
Use the electrode holder clamps without protruding bracket screws, which meet the current safety
standards.
Make sure that the ON/OFF switch
not plugged into the socket.
Put on appropriate protective clothing in accordance with the specifi cations and prepare your work
station.
Connect the earth terminal
Clamp the electrode into the electrode holder
Connect the mains cable
Switch the device on by setting the ON/OFF switch
Adjust the welding current using the rotary knob
onto the device (see Fig. C1 – C4).
1
7
onto the welding mask
11
must be pushed in from the top.
11
is set to position "O" ("OFF") or that the power cable
9
to the workpiece.
4
to the socket.
10
, as shown in Fig. A.
, as shown in Fig. B.
7
in fully, gently press on the outside of the
11
.
5
to the "I" ("ON") position.
9
depending on the electrode being used.
3
is
10
GB/IE/NI
15

Werbung

Inhaltsverzeichnis
loading