Do not use the cable for purposes for which it is not meant.
Protect the cable against heat, oil and sharp edges. Do
not use the cable to pull the plug from the socket.
Regularly check the extension cables and replace them if
they are damaged.
Do not use any defective connection cables.
When working outdoors, only use extension cables especially
approved and appropriately labelled for outdoor use.
Do not set up any provisional electrical connections.
Never bypass protective devices or deactivate them.
Only hook up the machine by means of a fault-current cir-
cuit breaker (30 mA).
The electrical connection or repairs to electrical parts of
the machine must be carried out by a certified electrician or
one of our customer service points. Local regulations –
especially regarding protective measures – must be ob-
served.
Repairs to other parts of the machine must be carried out
by the manufacturer or one of his customer service points.
Use only original spare. Accidents can arise for the user
through the use of other spare parts. The manufacturer is
not liable for any damage or injury resulting from such ac-
tion.
C
o
m
m
i
s
s
i
o
n
i
n
g
C
o
m
m
i
s
s
i
o
n
i
n
g
Check that the machine is completely and correctly assem-
bled.
To avoid toppling, place the shredder on a firm horizontal
surface.
The machine should only be operated in the open. Always
maintain a safe distance (at least 2 m) from walls or other
fixed objects.
Before each use, check
Connection cables for defects (cracks, cuts, etc.).
Do not use any defective cables.
There are no damage at the machine
(see safety instructions).
All screws are tight.
Mains connection
Compare the voltage given on the machine model plate e.g.
230 V with the mains voltage and connect the machine to the
relevant and properly earthed plug.
Only use extension cables with sufficient core cross-section.
In case of disadvantageous power system conditions short-
term voltage reductions can occur during the starting process
of the device which can influence other devices (e.g. jittering
of a lamp). No failures are expected when the house service
connection has a continuous currect-carrying capacity greater
than 100 A per phase.
Mains fuse
2300 W
16 A time-lag
2500 W
16 A time-lag
2800 W
16 A time-lag
On / Off switch
Do not use any device where the switch can not be switched
on and off. Damaged switches must be repaired or replaced
immediately by the customer service.
Switch on
Press the green button I .
Switch off
Press the red button 0 .
Restart protection in case of power
failure
In case of a power failure, the device switches off automatically
(zero-voltage initiator). To restart, press the green button again.
Motor protection
The motor is equipped with a safety switch and switches off
automatically when overloaded. After a cooling-down break
(approx. 5 min), the motor may be restarted. Press the
1. reset button (motor protection)
2. green button I to restart.
Use a tamper or hook to remove jammed objects from the
hopper or ejection slot.
Retaining basket
The integrated retaining basket is equipped with a locking
lever and a safety cut-out device.
Power off the device before attaching or removing the re-
taining basket.
Retaining basket locked and fixed connected to
the device.
Switzerland
UK
10 A time-lag
13 A time-lag
13 A time-lag
13 A time-lag
13