IX- TROUBLESHOOTING

NOTE : see Torqeedo's user Manual, chapter Troubleshooting.
ERROR
System display does not switch
on after turning the key switch
Bilge fan does not operate after
pressing the bilge fan switch
Bilge pump does not operate
after pressing the bilge pump
switch on Manual Mode
No water flow when the bilge
pump is running with water in
the bilge
Reverser actuator does not
operate after pressing the tilt
button
Boat slows down
TROUBLESHOOTING
CAUSE
Circuit breaker is off
Battery charge is too low
Circuit breaker is off
Battery charge is too low
Circuit breaker is off
Battery charge is too low
Page 47 / 47
CHECKING/CORRECTION
Check the boat circuit breaker and
switch it on if necessary.
Check the charge state of the 12V
battery. If the charge is lower than
11V, charge using an external
charger unit if necessary.
Check the 50A fuse on the harness
and replace it if defective.
Check the boat circuit breaker and
switch it on if necessary.
Check the 50A fuse on the harness
and replace it if defective.
Check the charge state of the 12V
battery and charge it if necessary.
Check the 5A bilge pump fuse and
replace it if defective
Check the bilge pump strainer and
clean it out if necessary.
Check the boat circuit breaker and
switch it on if necessary.
Check the charge state of the 12V
battery. If the charge is lower than
11V, charge using an external
charger unit if necessary.
1- Check the 50A fuse on the
harness and replace it if defective.
2- Check the 16A actuator reverser
fuse and replace it if defective.
Check the maintenance hydrojet
hatch and remove seaweeds or
debris if necessary. See chapter
"Propulsion".