Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Repairing; Troubleshooting - Stihl RE 100.0 PLUS CONTROL Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für RE 100.0 PLUS CONTROL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
English
1
► Remove the seal (1) from the filter housing (3).
► Take the filter (2) out of the filter housing (3).
► Rinse out the seal (1) and the filter (2) under
running water.
► Grease the gasket (1) with a fitting grease.
► Reassemble the water filter.

15 Maintenance

15.1
Maintenance intervals
Maintenance intervals depend on the ambient
conditions and the operating conditions. STIHL

17 Troubleshooting

17.1
Correcting faults in the pressure washer
Fault
The pressure washer
does not start alt‐
hough the spray gun
trigger is squeezed.
The pressure washer
does not start when
switched on. The
electric motor buz‐
zes.
42
2
3
Cause
The mains plug of the connecting
cable or extension cord is not plugged
in.
The circuit-breaker (fuse) or the resi‐
dual current circuit breaker has trip‐
ped. There is an electrical overload or
a fault in the circuit.
The fuse rating of the socket is too
low.
The extension cord has an incorrect
cross-section.
The extension cord is too long.
The electric motor is too warm.
The mains voltage is too low.
The extension cord has an incorrect
cross-section.
The extension cord is too long.
recommends the following maintenance inter‐
vals:
Monthly
► Clean water intake screen.

16 Repairing

16.1
Repairing the pressure washer
The user cannot personally repair the pressure
washer and accessory.
► If the pressure washer or accessory is dam‐
aged: Do not use the pressure washer or
accessory. Consult a STIHL servicing dealer.
Remedy
► Plug in mains plug of connecting
cord or extension cord.
► Look for cause of tripping and
remedy it. Engage circuit-breaker
(fuse) or the residual current circuit
breaker.
► Switch off other loads connected to
the same circuit.
► Plug the connecting cable into a
socket with the correct fuse rating,
18.1.
► Use an extension cord with an ade‐
quate cross-section,
► Use an extension cord with the cor‐
rect length,
► Allow the pressure washer to cool
for 5 minutes.
► Clean the nozzle.
► Squeeze and hold the spray gun
trigger and switch on the pressure
washer.
► Switch off other loads connected to
the same circuit.
► Use an extension cord with an ade‐
quate cross-section,
► Use an extension cord with the cor‐
rect length,
15 Maintenance