Description and function
en
Deblocking
When the motor is blocked, the pump automatically starts a specific routine with a
high torque to remove the blockage.
The routine takes a maximum of around 30 minutes.
See section "Faults, causes and remedies" for the manual activation procedure.
Factory setting
This function makes the pump run with the factory settings (delivery condition).
This function is present only on version "F02".
See section "Commissioning" for the activation procedure.
Key lock
Locks the pump's current settings and protects against undesired or unauthorised ad-
justment of the pump.
This function is present only on version "F02".
See section "Commissioning" for the activation procedure.
Pump kick
Prevents deposits that can form during a prolonged standstill.
The pump switches itself on for a short time every day during the standstill.
The pump must remain powered all the time to enable this function.