Herunterladen Inhalt Inhalt Diese Seite drucken

Signal Acquisition; Description; Teach Methods; Teach - Balluff BAE SA-OH-061-UA-DP02 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für BAE SA-OH-061-UA-DP02:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BAE SA-OH-061-UA-... / BAE SA-OH-062-IC-...
Photoelectric Sensors
7
Menu structure (continued)
7.2

Signal Acquisition

7.2.1

Description

Sensor Principle
The sensor performs measurement value acquisition as a
continuous signal that is evaluated for switching signal
generation.
The following teach methods are available: Single value
teach and dynamic teach.
7.2.2

Teach Methods

For a successful teach-in as well to directly set a setpoint,
the following conditions must be met:
The setpoint that is to be taught must be in the validity
range of the measurement value signal.
An active teach process is indicated by illumination of the
red LED. If the red LED flashes, the currently pending
measurement value is outside of the validity range.
Single Value Teach
With single value teach, the switching point (setpoint) is
defined via a teach point. Moreover, this is a static process,
i.e., the measurement value is constant during the teach
phase.
Dynamic Teach
With this process, no static teach points are recorded,
unlike with the previous methods; rather, multiple measure-
ment values are recorded over a defined period of time.
For this purpose, the minimum and maximum values are
determined. The average value of these two extrema is
used to form the new switching point (setpoint). The
maximum acquisition time is 60 seconds, then the
teaching process is aborted.
External Dynamic Teach
start
t
t
1
2
t
= 0.1 ... 4.5 s
1
t
= 0.1 ... 60 s
2
t
= 0.1 ... 1.5 s - volatile storage
3
t
= 2.0 ... 4.5 s - permanent storage
3
Fig. 7-7:
External Dynamic Teach with timing
14
english
stop
storage
t
3
t
Signal value
7.3

Teach

TEACH
TEA
1-V-Teach
1VT
Dyn.Teach
DYT
Man.Adjust
AMP
7.3.1

Teach Menu

Value
Meaning
1-Value-Teach
1-V-Teach
Dyn.Teach
Dynamic Teach
Man Adjust Amplification
Tab. 7-2:
Menu structure – Teach Menu
7.3.2

Amplification

The amplification of the receiver signal can be set in the
range of 10..256 (1000).
10: Lowest amplification: Smallest signal, less noise, low
range
256: Highest amplification: Largest signal, more noise, high
range
1000: additional computational amplification, more noise,
highest range (only in "Advanced Amplification Mode")
Teach
Do-1-V-T
Start-Dyn. , Stop-Dyn.
Adjust Amplification
Description
Do-1-V-T
Start-Dyn.
Stop-Dyn.
Adjust Amplification

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis