Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting Guide - Kärcher IVM 40/24-2 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Permanently installed filters may only be
replaced by an expert in a suitable area,
e.g. a decontamination station.
2. Switch off the device at the power
switches.
3. Pull out the mains plug.
4. Unlock and remove the suction head.
5. Unlock and remove the spacer.
6. Remove the main filter.
7. Check the sealing ring for damage.
8. Remove any dirt deposits from the clean
air side.
9. Fit the new main filter in reverse order.
Make sure that the filter hold-down de-
vice is centred in the filter pockets.
10.Fit and lock the spacer.
11.Fit and lock the suction head.
Replacing the H filter
1. Secure the device with the parking
brakes.
2. Switch off the device at the power
switches.
3. Pull out the mains plug.
Illustration G
4. Unlock and remove the suction head.
5. Unscrew the hexagon screw anticlock-
wise using a suitable tool.
6. Remove the seals and the filter from the
7. Remove any dirt deposits from the clean
air side.
8. Fit the new H filter in the reverse order.
Make sure that the seals are correctly
seated.
9. Apply a suitable agent (e.g. Loctite 243)
to the thread of the hexagon screw to
prevent unintentional loosening.
10.Tighten the hexagon screw clockwise.
11.Fit and lock the suction head.
1. Secure the device with the parking
brakes.
Illustration B
2. Pull the bow handle up.
The dirt receptacle is unlocked and low-
ered.
20
Illustration C
Illustration E
tie.
Illustration D
8. Insert the new dust bag in the dirt recep-
tacle and carefully place it against the
container wall and the container floor.
WARNING
receptacle

Troubleshooting guide

DANGER
Unintentional start-up of the device /
electric shock
Unintentional start-up of the suction motor
can cause injuries. Voltage present on
electrical parts can cause an electric shock.
Switch off the device and unplug the mains
plug before performing any work on the de-
vice.
Have all checks and work on electrical
parts performed by an qualified technician.
Note
The device must be switched off immedi-
ately in the event of a malfunction. The mal-
function must be eliminated before
switching the device on again.
If the malfunction cannot be corrected, the
device must be checked by the Customer
Service department.
English

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ivm 40/24-2 h

Inhaltsverzeichnis