Herunterladen Inhalt Inhalt Diese Seite drucken

Finalizing Of Engine Assembly; Verification Or Replenishing Of Oil Level In Gear Compartment - Rotax 125 MAX DD2 Installationsanleitung

Rotax-motor type
Vorschau ausblenden Andere Handbücher für 125 MAX DD2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Finalizing of engine assembly

For technical-transport-reasons some items are included loose in the shipment and have to be
fitted as follows after receipt of engine.
Mount upper part of engine mounts with 4 x M8 screws (strength category min.
10.9) to the crank case.
Note:
The engine mount is chassy specified and therefore not content of the delivere by
Rotax
Note:
Hand screw the 4 x M8 screws of the upper engine mount only, tightening to the full
specification will be done later, see section 6
Attention: For assembling the engine mounts follow the instruction of the chassis
manufacturer.

4. Verification or replenishing of oil level in gear compartment

The gear compartment is already filled with the appropriate amount of oil 150 CC (0,039 gal.) by
the engine manufacturer. However before the engine is installed in the frame, the oil level must be
verified or replenished.
Place engine on a horizontal surface.
Attention: When placing the engine on a horizontal surface, take care not to damage the pick
up for the ignition which is mounted on the bottom of the crank case.
Oil level can be checked on inspection glass (1). Oil level should reach
approximately to the middle of the inspection glass. (See Fig.1)
Fig. 1
Note:
Oil capacity by new filling is 150 CC (0,039.gal)
Seite/page 57/100
Operating Instructions 125 MAX DD2
Ausgabe/edition 01/2006

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading