22 | Denoxtronic 2.1 | Devices and components
3.5

Pressure gauge 0 986 610 510

The pressure gauge is used for AdBLue supply modules
to test various system operating pressures, the
functioning of the switchover valve and suction.
!
The pressure gauge is specially designed for testing
AdBLue supply modules. It is impermissible to use a
different pressure gauge.
i
Detailed instructions on use and handling can be
found in the separate ESI[tronic] repair instructions
Denoxtronic 2.1.
Fig. 5:
Pressure gauge 0 986 610 510
i
The measuring accuracy of the pressure gauge
must be tested regularly by a certified inspection
authority. This is the responsibility of the user.
i
If the pressure gauge is defective, it must be
replaced with a new one.
3.5.1

Attaching the pressure gauge

The integrated hook is used to attach the pressure
gauge to the Denoxtronic test device 0 986 613 880.
|
1 689 989 404
2019-03-01
3.6

Mounting support 0 986 611 249

The mounting support (fig. 6, item 1) is fastened to the
front left of the prepared working surface of the test
device 0 986 613 880 (4 M8 screws).
The rod 0 986 610 981 (fig. 6, item 3) is inserted into
the round receptacle of the mounting support and
clamped tight. The base plate 0 986 613 866 (fig. 6,
item 2) is fixed to the rod with two screws (M10).
The AdBlue supply module is attached to the base plate
for testing and repairs. The AdBlue supply module can
be moved into the corresponding position for use by
turning the rod and the lever on the mounting support
during testing and repairs.
!
When loosening and turning the rod on the
mounting support, always hold the base plate or
the AdBlue supply module with one hand to prevent
uncontrolled tipping.
Fig. 6:
Mounting support 0 986 611 249 on the test device
0 986 613 880
1 Mounting support 0 986 611 249
2 Base plate 0 986 613 866
3 Rod 0 986 610 981
i
Detailed instructions on use and handling can be
found in the separate ESI[tronic] repair instructions
Denoxtronic 2.1.