If necessary, repeat the priming operation after the
pump has been first emptied and then completely filled
with clean cold water.
ATTENTION: At first priming, once the pump
has been primed, it may be necessary to stop
the pump, wait a few seconds and then restart
EN
it with all taps opened, in order to eliminate the
air inside the pump casing completely.
During the self-priming time, if the pump does not prime
within 2 minutes, Er07
"not primed" appears. Press the enter button for the
reset
and the button start
8.6. Vessel pressure
Once the new re-start pressure is entered (parameter
UP01-UP02), the tank preloaded pressure must be
changed to 0,5 bar lower than re-start pressure (i.e.
2,9 bar re-start pressure, tanks to be preloaded at 2.4
bar) par. 14 fig. 6.
ATTENTION: Do not preload the diaphragm of the tank
over 3,5 bar; if an higher pressure is required, install an
external tank.
If the pump works for long periods of time with a flow rate
of 2 liters/min or lower it is necessary to install a tank of
at least 8 liters.
8.7. Gate valve regulation
With the gate valve completely open or with an outlet
pressure lower than the minimum pressure shown on
the name-plate, the pump may be noisy. To reduce
noise regulate the delivery gate valve.
8.8. Abnormal operation
Never run the pump for more than five minutes
with a closed gate valve.
Prolonged operation without a change of water in the
pump causes dangerous increases of temperature and
pressure.
Prolunged operation with a closed delivery port
causes breakage or damage to parts of the pump.
When the water is overheated due to prolonged
operation with a closed port, stop the pump before
opening the gate valve.
Do not touch the fluid when its temperature is
higher than 60 °C.
Do not touch the pump when the surface
temperature is higher than 80 °C.
Wait until the water has cooled inside the pump before
starting again or opening the draining and filling plugs.
8.9. Switch off of the pump
ON
The appliance must be switch off every time
there are faults. (see troubleshooting).
The product is designed for a continuous duty, the
switch off is performed by disconnecting the power
supply by means the expected disconnecting devices.
(see paragraph "6.5 Electrical connection").
Page 16 / 80

9. MAINTENANCE

Before any operations it's necessary to disconnect the
power supply.
If required ask to an electrician or to an expert
technician.
In case of extraordinary maintenance, or maintenance
to restart the pump.
operations that require part-removing, the operator
must be a qualified technician able to read schemes
and drawings.
It is suggest to register all maintenance operation
executed.
Maintenance operations that are not described in
this manual must be made only by special personnel
authorized by Calpeda S.p.A.
For further technical information regarding the use or
the maintenance of the device, contact Calpeda S.p.A.
9.1. Routine maintenance
When the pump remains inactive it must be
emptied completely if there is a risk of freezing
(par. 14 fig. 5).
Before restarting the unit, check that the shaft is not
jammed and fill the pump casing completely with liquid.
9.2. Vessel maintenance
Inspect the preloaded pressure of the membrane
inside the pump (par. 14 fig. 6)
9.3. Dismantling the system
Close the suction and delivery gate valves and drain
the pump casing before dismantling the pump.
Every maintenance operations, cleaning or
reparation executed with the electrical system
under voltage, it could cause serious injuries
to people.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid
a hazard.
During maintenance keep particular attention in
i
order to avoid the introduction of small external
parts, that could compromise the device safety.
It is forbidden to execute any operations with
the direct use of hands. Use water-resistant,
anti-cut gloves to disassemble and clean the
filter or in other particular cases.
During
maintenance
i
personnel is not allowed.
OFF
Before
every
disconnect the power supply and make sure
that the device could not accidentally operate.
In the case of water containing chloride
(chlorine, sea water), the risk of corrosion
increases in stagnant water condictions (also
with an increase in temperature and decrease
of pH value). In these cases, if the pump
remains inactive for long periods, it must be
emptied completely and, preferably, dried.
For good measure, as in the case of temporary
operation with dirty liquids, run the pump
briefly with clean water to remove deposits.