Herunterladen Inhalt Inhalt Diese Seite drucken

Vacuum Blower Vge Sb-L 4 Dg; Troubleshooting - probst JWK Serie Betriebsanleitung

Jumbo wanderkran
Inhaltsverzeichnis

Werbung

Vacuum blower VGE SB-L 4 DG

7
Vacuum blower VGE SB-L 4 DG
→ see separate operating instructions (see Appendix).
7.1

Troubleshooting

The device must be serviced and repaired by trained and authorized personnel only.
Error
Blower does not suck
Vacuum pressure is not reached (at the lifting
device connected)
5280.0021
Cause
phase connection of blower
faulty
lever on star-delta switch is not
in the "delta" position
dust filter is choked
V3
Remedy
transpose power connector on
the star-delta switch by 180°
push lever to "delta" position
blow out the dust filter, replace
if necessary
24 / 28
GB

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Jwk-80/250-5 eu

Inhaltsverzeichnis