M-LINE
• Always have repairs carried out by a qualified service engineer.
• The plug must be taken out of the socket if the appliance has to be opened for
cleaning or repairs.
The manufacturer cannot be held liable for losses caused as a result of failure to observe
these safety instructions.

Safeguards

The appliance is fitted with the following safeguards:
Dry-boil protection (14)
This appliance is equipped with a dry-boil protection. This protection triggers if the
heating element overheats owing to a fault. Once the fault has been resolved, the dry-
boil protection can be reset at the back of the appliance. The most common cause of the
dry-boil protection being triggered is not descaling the heating system in time.
If the heating system does not switch back on, proceed as follows:
1.
Allow the appliance to cool down.
2.
Unscrew the protective cap.
3.
Press the button which is now visible and firmly screw the protective cap back on.
If the dry-boil protection triggers owing to increased scale deposits, descale the appli-
ance. See chapter 6.2 Consult your dealer if the fault was caused by a problem other
than the dry-boil protection being triggered.
On/off switch (1)
The on/off switch is used to switch the appliance on and off. Remember that the appli-
ance can still be live after switching it off! For this reason you should always remove the
plug from the socket to render the appliance voltage-free.
Start/stop button (5.5)
The coffee making process can be interrupted at any point using the start/stop button
located on the control panel.
Jug detector (9)
This appliance is fitted with a jug detector that operates the leak stop under the filter.
This jug detector also ensures that the appliance only makes coffee if there is a jug
under the filter. If the jug is removed during the coffee brewing process, the process will
be interrupted and the filter will stop dripping.
Overflow safeguard
The amount of water required is regulated and monitored by flow and level sensors.
If one of the two sensors detects an irregularity, the appliance switches off and both indi-
cator lights will flicker.
2015/02 Rev. 4.0