Herunterladen Inhalt Inhalt Diese Seite drucken

Before Commissioning; Attachment And Operation - Parkside PKO 24 B2 Bedienungs- Und Sicherheitshinweise Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 56
The noise emission values have been determined in accordance
with EN ISO 3744:1995.
Wear hearing protection.
Excessive noise can result in a loss of hearing.

8. Before commissioning

• Open the packaging and carefully remove the device.
• Remove the packaging material, packaging and transport
safety devices (if applicable).
• Check that the delivery is complete.
• Check the device and accessory parts for transport damage.
• If possible, keep the packaging until the expiry of the
warranty period.
DANGER
The device and the packaging are not children's
toys! Do not let children play with plastic bags,
films or small parts! There is a danger of choking
or suffocating!
Before connecting the machine, make certain that the data on
the type plate matches with the mains power data.
• Prior to initial commissioning, remove the transport lid (20a)
and fill the compressor pump housing with oil as described
in item 9.4.
• Check the device for transport damage. Report any damage
immediately to the transport company which was used to
deliver the compressor.
• Install the compressor near the point of consumption.
• Avoid long air lines and supply lines (extension cables).
• Make sure that the intake air is dry and free of dust.
• Do not install the compressor in a damp or wet room.
• The compressor may only be used in suitable rooms (with
good ventilation and an ambient temperature from +5°C
to 40°C). There must be no dust, acids, vapours, explosive
gases or inflammable gases in the room.
• The compressor is designed to be used in dry rooms. It is
prohibited to use the compressor in areas where work is
conducted with sprayed water.
• The oil level in the compressor pump housing must be
checked before using the machine.

9. Attachment and operation

m Attention!
Always make sure the device is fully assembled
before commissioning!
You require the following for assembly:
1x open-ended spanner 13 mm
1x Phillips screwdriver
(not included in the scope of delivery)
9.1 Fitting the wheels (fig. 4)
• Fit the supplied wheels (11) as shown.
9.2 Fitting the supporting feet (fig. 5)
• Fit the supplied supporting feet (9) as shown.
6
GB
9.3 Fitting the air filter (fig. 6, 7)
• Remove the transport lid (15a) and screw the air filter (15)
to the equipment.
9.4 Filling the oil (fig. 8, 9)
• Remove the transport lid (20a) of the oil filling opening (20).
• Fill the included compressor oil into the compressor pump
housing and insert the supplied oil sealing plug (16) into the
oil filling opening (20).
9.5 Mains connection
• The compressor is equipped with a mains cable with
protective contact plug. This can be connected to any 220 ‒
240 V∼ 50 Hz protective contact socket, with fuse protection
of at least 16 A.
• Before you use the machine, make sure that the mains voltage
is the same as the operating voltage and the machine power
on the rating plate.
• Long supply cables, extensions, cable reels, etc. cause a
drop in voltage and can impede motor start-up.
• At low temperatures below +5°C, sluggishness may make
starting difficult or impossible.
9.6 On/off switch (fig. 2)
• Pull the on/off switch (17) upwards to switch on the
compressor. To switch off the compressor, press the on/off
switch (17) down.
9.7 Setting the pressure (fig. 1, 3)
• Use the pressure regulator (5) to set the pressure on the
pressure gauge (4).
• The pressure set can be drawn from the quick coupling (3).
• The vessel pressure can be read off at the pressure gauge
(6).
• The vessel pressure is drawn from the quick coupling (7).
9.8 Setting the pressure switch (fig. 1)
• The pressure switch (2) is set at the factory.
Cut-in pressure approx. 8 bar
Cut-out pressure approx. 10 bar
9.9 Fitting the compressed air hose (fig. 1, 3)
• Connect the plug nipple (14a) of the compressed air hose
(14) to one of the quick couplings (3, 7). Then attach the
compressed air tool to the quick coupling (14b) of the
compressed air hose (14).
9.10 Thermal protector
The thermal protector is built into the device.
If the thermal protector has tripped, proceed as follows:
• Pull out the mains plug.
• Wait about two to three minutes.
• Plug the device in again.
• If the device does not start, repeat the process.
• If the device does not start again, switch the device off and
on again using the on/off switch (17).
• If you have carried out all of the steps above and the device
still does not work, contact our service team.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis