5. Technical data

Mains connection:
Motor rating kW:
Operating mode:
Compressor speed min
-1
:
Operating pressure bar:
Pressure vessel capacity (in liters):
Theoretical intake capacity (l/min): approx. 270
Effective delivery rate at 7 bar:
Sound power level L
in dB:
WA
K
uncertainty:
WA
Protection type:
Weight of the unit in kg:
Oil (15W 40):
The product meets the requirements of EN
61000-3-11 and is subject to special
connection conditions. This means that use
of the product at any freely selectable
connection point is not allowed.
Given unfavorable conditions in the power
supply the product can cause the voltage to
fluctuate temporarily.
The product is exclusively intended for use
at connection points that have a continuous
current-carrying capacity of at least 100 A
per phase.
As the user, you are required to ensure, in
consultation with your electric power
company if necessary, that the connection
point at which you wish to operate the
product meets the specified requirements.
24.02.2011
10:59 Uhr
Seite 11

6. Before starting the equipment

Check the equipment for damage which
230 V ~ 50 Hz
may have occurred in transit. Report any
1.8 kW
damage immediately to the transport
S1
company which was used to deliver the
compressor.
2850
Install the compressor near the point of
max. 8
consumption.
24
Avoid long air lines and supply lines
(extension cables).
Make sure that the intake air is dry and
90l/min
dustfree.
97
Do not install the compressor in a damp or
4 dB
wet room.
The compressor may only be used in
IP20
suitable rooms (with good ventilation and an
approx. 26
ambient temperature from +5 °C to 40 °C).
0.25 l
There must be no dust, acids, vapors,
explosive gases or inflammable gases in the
room.
The compressor is designed to be used in
dry rooms. It is prohibited to use the
compressor in areas where work is
conducted with sprayed water.
The oil level in the compressor pump has to
be checked before putting the equipment
into operation (see 9.4).

7. Assembly and starting

Important!
You must fully assemble the appliance
before using it for the first time!
You will require the following tools for assembly
and installation:
2 x open-ended wrench size 17 mm (not
included)
7.1 Fitting the wheels (11)
Fit the supplied wheels as shown in Figure 5.
7.2 Fitting the supporting foot (8)
Fit the supplied supporting foot as shown in
Figure 6.