The < (Previous) and > (Next) buttons center the waveform in the display at the position of the previous or next measurement point in the
record (for measurements that take more than one measurement per acquisition).
The Min' and Max' navigation buttons center the waveform in the display at the minimum or maximum value for that measurement in the
current acquisition.
The prime symbol (') shown on measurement readings and Min/Max buttons indicates that the value shown (or moved to in the case of
Min/Max buttons and waveforms) is from the current acquisition. Lack of a prime symbol means the value is from all acquisitions.
The Measurement badge displays Status and Failures information when pass/fail testing is enabled through the configuration menu. The
Status line shows Pass (green) or Fail (red) according to the conditions defined in the Pass/Fail Testing panel. The number of Failures
are displayed when statistics are shown in the badge. The Pass/Fail status, number of Failures, and the Limit(s) set in the Pass/Fail
Testing panel are available in the Measurement Results table.
Measurement badges are listed in the order created, starting at the top of the Results bar. Deleting a Measurement badge does not
change the order or names of the remaining badges.
You can drag Measurement badges to change their position in the Results bar and open the badge right-click menu to access a
quick-action menu.
There are two ways to delete Channel and Waveform badges.
Right-click the badge and turn it off.
Flick the badge off the right edge of the display to remove it from the Results bar. Flicking left from the right edge of the Results bar
recovers the badge. Badge recovery is only possible within 10 seconds of removal.
Mask Test Badge
The mask test results and measurement statistics are displayed in the Mask Test badge in the Results bar. The badge is created when the
first segment of a mask is defined.
Badge readout
Label
Wfms
Failed
Hits (optional readout)
Total
Status
5 Series B Mixed Signal Oscilloscopes MSO54B, MSO56B, MSO58B Quick Start Manual
Description
A label defined in the badge configuration menu.
The total number of waveforms tested against the mask.
The number of waveforms that contained one or more samples that violated the mask.
A row is created for each segment that makes up the mask. The number displayed is the
number of times that segment has been hit.
The total number of hits on all segments.
The status of the mask test. Either Pass (green) or Fail (red) is displayed.
Getting acquainted with your instrument