9.
OPERATING CHECKS
9.1.
MALFUNCTIONS SELF-DIAGNOSTIC
The display located on the control panel (Photo 7)
also has the function of showing any active alarms on
the machine concerning to the control board oper-
ation; in case of alarm will be shown the code and a
brief description of the error.
Here below is the list of error messages with the cor-
responding diagnostic:
Alarm #id
1. Traction motor shutdown
2. Brushes motor shutdown
3. Suction motor shutdown
4. Traction motor I
t triggered
2
5. Brushes motor I
2
t triggered
6. Suction motor I
2
t triggered
7. Brushes motor switch off
for run down battery
8. Suction motor switch off for
run down battery
9. Machine stop for run down
battery
10. Machine stop for over
charged battery
11. Board temperature too
high (traction stopped)
13. Board temperature too
high (traction lowered to
50%)
14. Floating switch error
15. Start error (key switch
on with operator presence
pressed)
16. Solid board in standby
18. CanBUS communication
interrupted
27. Traction motor discon-
nected
28. Battery overcurrent
29. Low battery current
Meaning
Amperometric protection
traction motor
Amperometric protection
Brushes motor
Amperometric protection
suction motor
Amperometric protection
traction motor
Amperometric protection
Brushes motor
Amperometric protection
suction motor
Low voltage
Low voltage
Low voltage
Overcurrent
Control board overheating
(traction stopped)
high temperature detect on
control board (traction lowe-
red to 50%)
Stop signal from floating
switch
User lever pressed before
control board check
Control board freeze status
for excessive stand-by
Lack
of
communication
dashboard-board
No traction motor signal
Overcurrent
Low voltage
Solution
Check usage mode of the traction function. High working current has
been detected by the traction motor.
Check usage mode of the brushes function. Detected elevated work
current by the brushes motor.
Check vacuum motor absorption. Detected elevated work current by
the suction motor.
Check usage mode of the traction function. High working current has
been detected by the traction motor.
Check usage mode of the brushes function. Detected elevated work
current by the brushes motor.
Check vacuum motor absorption. Detected elevated work current by
the suction motor.
Low voltage detected on function board (<90%). Check batteries and
batteries connections.
Low voltage detected on function board (<80%). Check batteries and
batteries connections.
Low voltage detected on function board. Check batteries and batteries
connections.
Overvoltage detected on function board. Check batteries and batte-
ries connections.
check brush motor/traction motor absorption
check brush motor/traction motor absorption
To empty recovery tank
Reboot scrubber drier (do not press user lever before control board
check)
Reboot scrubber drier
Check connections between the function board and dashboard.
Check connections and traction motor status.
Overvoltage detected on function board. Check batteries and batte-
ries connections.
Low voltage detected on function board. Check batteries and batteries
connections.