  • DEUTSCH, seite 67
of time, disconnect them and restore the charge
within the time limits specified for the type of battery
used (generally and as a precaution, no more than 3
months for Pb-acid/GEL/AGM batteries, 6 months for
Li-ion batteries).
The manufacturer accepts no liability for damage to
batteries caused by failure to follow this procedure.
7.8.

PERIODIC MAINTENANCE

For all the operations described herein, refer to the in-
structions and detailed warnings in the relative sections.
7.9.

RECOMMENDED SPARE PARTS

You'll always be able to use your machine as effi-
ciently as possible by maintaining a stock of the most
common consumable materials and by scheduling
routine and extraordinary maintenance.
Contact your dealer for a list of these spare parts
8.
OPERATING CHECKS INFORMATIONS
8.1.
THE MACHINE DOESN'T WORK
 The key isn't inserted or correctly turned.
 Insert and turn the key to position ON.
 The battery connector is disconnected or poorly
attached to the main wiring connector.
 Firmly connect the two connectors.
 The machine is charging.
Remove and wash the squeegee
Drain the recovery tank
Drain, rinse with clean water or sanificate the recovery tank
Charge the batteries
Check the acid level in the battery cells (if batteries are not maintenance-free)
Remove brushes and check for brush wear, foreign bodies and wrapped belts
Verify the machine general conditions.
Verify that suction hose and conduct are free from obstructions
Check the wear of the squeegee rubber blades
Open and clean the solution water filter
Clean the brush plate, squeegee support and squeegee
Check the lifting/lowering of the brush plate.
Check the lifting/lowering of the squeegee.
Grease the moving parts.
Check the control cable for the opening of the solution water tap.
Descale water hoses.
 Complete the charging operation.
 The batteries are discharged.
 Charge the batteries.
8.2.
THE BRUSH DON'T ROTATE
 The brush motor switch is not selected.
 Press the button to activate the brushes.
 The brush motor thermal breaker tripped; the
motor overheated.
 Troubleshoot the cause (cords or similar items that
impede movement, surface too rough, etc.) and
press the reset breaker (the first from the top).
 The motor relay or the brush motor is broken.
 Replace it.
8.3.
NOT ENOUGH OR TOO MUCH CLEANING
SOLUTION
The solution water tank is empty.
 Fill the solution water tank after having emptied
the recovery tank.
 The solution water valve is closed or almost closed.
 Adjust/increase the detergent solution outlet flow
by turning the flow adjustment lever.
 The solution water filter is dirt and clogged in some
point.
 Open the filter and clean it removing the dirt.
When needed
X
X
41
After every use
Weekly
X
X
X
X
X
X
X
X
X
Monthly
X
X
X
X
X
X