5.2.

BATTERY CHARGER CONFIGURATION

We recommend to call the assistance centre or a tech-
nician if you have problems with the setting given.
The machine is equipped with a battery charger con-
figurated for GEL maintenance free battery.
If you whish to equip the machine with Pb-Acid bat-
teries, AGM or OPTIMA batteries, it is necessary to
change the battery charger settings as follows:
DISPLAY OF THE BATTERY CHARGER SETTINGS
The battery charger settings are shown by the blin-
king of the LED indicator when the battery charger
is switching on:
- the RED LED indicator ( Photo 13 -B ) flashes 2
times = the battery charger is set for PB-Acid bat-
teries
- the GREEN LED indicator ( Photo 13 - C ) flashes 2
times = the battery charger is set for GEL/AGM or
OPTIMA batteries.
- Calibration change when batteries are disconnected.
The battery charger settings will be displayed even
if the battery is not connected.
DIP-SWITCH CONFIGURATION FOR CHARGING
CURVE SETTINGS FOR BATTERY CHARGER CBHD1-XR
24V 12A
Refer to the relevant manufacturer's manual provided.
To set the charging curve type for Pb-Acid, GEL/AGM
or OPTIMA batteries it is necessary to operate on the
dip-switches placed inside the battery charger ( Photo
13 - D ) ( Photo 13 - F ).
To access the dip-switches it is necessary to remove
the lower panel of the battery charger ( Photo 13 - A );
it is also possible to reach the dip-switches by remov-
ing the plastic cap ( Photo 13 - E ).
To configurate the charging curve related to the
different battery type it is necessary to set the dip-
switches as indicated in the Table A here below:
Photo 13
A) Battery charger cover
B) Red "LED" - Battery discharged
C) Green "LED" - Battery charged
D) Dip-Switches
E) Plastic cap
F) Dip-Switches for charging curve setting
B
A
Photo 13
SW 1
SW 2
ON
ON
ON
OFF
OFF
OFF
OFF
DIP 1
DIP 2
DIP 1
Table A
Battery type
Pb-Acid
GEL (default)
Exide-Sonnenshein-
Haze
AGM
Discover
AGM
Optima
5.3.
BATTERY CONFIGURATION
Photo 6. Keep A and B pressed and turn the power
on key. When "calibration" is displayed press F too. Re-
lease all the buttons. Press C+ or C- to select "Battery"
and press F to confirm. Press C+ or C- to select "Pb-
Acd" or "GEL", press F to confirm.
In the main menu select "exit" and press F to confirm.
5.4.

BOOST MODE

To activate the "boost" mode when the scrubber is
turned on, hold C + for about 3 seconds. The display
will the message "boost": the machine will have the
maximum traction power for 20 seconds to facilitate
the ascent on the ramps; then the standard power will
be automatically reset.
33
E
SW1
F
ON
OFF
OFF
DIP 2
Dip-Switch 1 Dip-Switch 2
ON
OFF
OFF
ON
C
OFF
OFF
ON
ON

Werbung