Decommissioning, disassembly, environmental protection

Personnel:
Protective equipment:
DANGER!
Risk of injury due to the disregard of the specified personal protective
equipment (PPE)!
For all disassembly work, please respect the use of the PSA which is specified
on the product data sheet.
9.1

Decommissioning

To take the equipment out of operation, proceed as follows:
1.
Before carrying out any subsequent work, switch off the electrical supply and secure
it against being switched on again.
2.
Relieve line pressure in the dosing system.
3.
Drain dosing medium completely from the suction lance
4.
Thoroughly rinse the suction lance to remove chemical residues.
5.
Remove the remaining processing materials and dispose of them in an
environmentally-friendly way.
Decommissioning, disassembly, environmental protection
n
Specialist
Chemical-resistant protective gloves
n
Protective eyewear
n
n
Safety shoes
27