Electrical safety:
Caution: to avoid accidents
and injuries from electric
shocks:
• If there are people in the water,
the device must not be opera-
ted. Risk of electric shock!
• After installation, the mains plug
must be freely accessible when
the equipment is in operation.
• Before operating your new
pump, have a specialist check:
-
The earthing, the protective
multiple earthing; the residual
current circuit breaking must
be compliant with the safety
regulations of the energy supply
company and function without
fault,
-
The protection of the electrical
plug connections from the wet.
• If there is a risk of flooding, fix
the plug connections in an area
that is safe from flooding. Risk
of electric shock.
• Ensure that the mains voltage
matches the specifications on
the rating plate.
• The electrical installation shall
be according to national wiring
rules.
• Connect the appliance only to
a power socket with a residual
current circuit breaker of rated
residual current no more than
30 mA; fuse min. 6 ampere.
• Check the device, power con-
nection cable and plug for
damage before each use. De-
fective mains connection cables
must not be repaired. They must
be replaced wit new ones. Ensu-
re that damage to your device is
repaired by an authorised speci-
alist.
• If the connection cable of this
device is damaged, it must be
replaced by the manufacturer or
their customer service or by a si-
milarly qualified person in order
to avoid hazards.
-
Do not use the mains connection
cable to pull the plug out of the
socket. Protect the mains con-
nection cable from heat, oil and
sharp edges.
• Use only extension cables that
are splash-proof and designed
for outdoor use. Always roll
out the cable drum completely
before use. Check the extension
cable for damage.
• Remove the plug from the mains
socket before carrying out work
on the device, if there is a leak
in the water system, during
work breaks and when not in
use.
• Mains connection cables must
not have a cross-section that
is smaller than those of rubber
hoses with the designation
H07RN8-F. The cable length
must total 10 m. The wire cross
section of the extension cable
must be at least 2.5 mm
• Protect mains cables and electri-
cal connections from moisture.
Make sure that mains connec-
tion cables and electrical con-
nections are located in a flood-
proof area.
GB
IE
.
2
21