BTS M30E0-_ _ _-H0001-S04G
Infrared Temperature Sensor
16

Technical Data

16.1

Dimensions

Dimensions in mm
16.2

Optical Data

Measuring range
Wavelength range
Peak wavelength
Distance Ratio
Resolution
16.3

Mechanical Data

Connection type
Housing material
Sensing surface material
Weight
Dimensions
Tightening torque
16.4

Electrical Data

Supply voltage U
B
Rated operational voltage U
No-load supply current I
Rated operating current I
Permissible load capacitance
Voltage drop U
at I
d
Output type
Short-circuit protection
Polarity reversal protected
Protection class
42
english
All manuals and user guides at all-guides.com
250...1250 °C (482...2282 °F)
1200...1700 nm
1550 nm
50:1 (Distance: light spot Ø)
1 °C, 1 °F, 1 %
M12 male, 4-pin
Stainless 1.4404 (X2 CrNiMo 17 12 2), aluminum 3.3206 (AlMgSi0,5)
(lens holder ring)
Glass N-BK7, coated
≤ 300 g
190 mm, Ø M30x1.5
80 Nm
10...30 V DC
24 V
e
≤ 70 mA
0
100 mA
e
≤ 70 nF
≤ 2.5 V
e
depending on type
yes
yes
II