BTS M30E0-_ _ _-H0001-S04G
Infrared Temperature Sensor
15
IO-Link Interface
15.4.4 Profile-specific Parameters
Subin-
Index
Name
dex
(dec)
(dec)
0x003A
Teach-In
0x00 (0)
(58)
Channel
0x003B
Teach-In
0x00 (0)
(59)
Status
0x01 (1)
Setpoint
0x003C
Value
(60)
(BDC1)
0x02 (2)
0x01 (1)
Switch-
point
0x003D
Configu-
(61)
0x02 (2)
ration
(BDC1)
0x03 (3)
0x01 (1)
Setpoint
0x003E
Value
(62)
(BDC2)
0x02 (2)
0x01 (1)
Switch-
point
0x003F
Configu-
(63)
0x02 (2)
ration
(BDC2)
0x03 (3)
www.balluff.com
All manuals and user guides at all-guides.com
Data
Name
Access Value Range (dec)
Format
UINT8
R/W
UINT8
R
Setpoint
SP1
UINT16
R/W
Setpoint
SP2
Switch-
point
UINT8
R/W
Logic
Switch-
point
UINT8
R/W
Mode
Switch-
point
UINT16
R/W
Hysteresis
Setpoint
SP1
UINT16
R/W
Setpoint
SP2
Switch-
point
UINT8
R/W
Logic
Switch-
point
UINT8
R/W
Mode
Switch-
point
UINT16
R/W
Hysteresis
Remarks
0x00 (0)
BDC1 (standard)
0x01...0x02 (1...2)
BDC1...BDC2
0xFF (255)
All BDC
see Smart Sensor
Profile
Sensor performs a
0x0000...0x0064
plausibility check.
(0...100 %)
The value range
0x00FA...0x04E2
depends on the
(250...1250 °C)
units selected (see
0x01E2...0x08EA
Parameter Unit
(482...2282 °F)
Style)
0x00 (0) = Normally
Open
0x01 (1) = Normally
Open
0x03 (3) = Two Point
Mode
0x0000 (0) = Standard
Hysteresis
Sensor performs a
0x0000...0x0064
plausibility check.
(0...100 %)
The value range
0x00FA...0x04E2
depends on the
(250...1250 °C)
units selected (see
0x01E2...0x08EA
Parameter Unit
(482...2282 °F)
Style)
0x00 (0) = Normally
Open
0x01 (1) = Normally
Open
0x00 (0) = Deactivated
0x03 (3) = Two Point
Mode
0x0000 (0) = Standard
Hysteresis
english
35