Index
Range
Value
------------------------------------------------------
0
0-15
0000h..F000h
1
0-15
0000h..0F00h
2
0-15
0000h..00F0h
3
0-15
0000h..000Fh
4
0-15
0000h..F000h
5
0-15
0000h..0F00h
6
0-15
0000h..00F0h
7
0-15
0000h..000Fh
[...]
252
0-15
0000h..F000h
253
0-15
0000h..0F00h
254
0-15
0000h..00F0h
255
0-15
0000h..000Fh
******************************************************
3.6 GDATA - Global Parameters
******************************************************
Note: Global Parameters are very unordered.
Index
Range
Value
------------------------------------------------------
0
reserved
1
1
2
0-2
A,B,Multi
3
0-127
1..128
4
1-17
omni,1-16
5
0-2
sound,multi,
combined
6
0-126
0..126
7
0-121
0..120, harmonic
8
0-120
0..120
9
0-120
0..120
10
0-120
0..120
11
0-120
0..120
12
0-127
0..127
13
reserved
14
reserved
15
52-76
-12..+12
16
54..74
430Hz..450Hz
17
0-127
0..127
18
0-127
0..127
19
1-9
exp2,exp1,lin,
log1,log2,fix32,
fix64,fix100,
fix127
20
0-9
off,exp2,exp1,
lin,log1,log2,
fix32,fix64,
fix100,fix127
21
1-5
exp2,exp1,lin,
log1,log2
22
reserved
Bedienhandbuch MicroWave II • MicroWave XT • XTk
Parameter
Index 1, most
significant nibble,
upper half
Index 1, least
significant nibble,
upper half
Index 1, most
significant nibble,
lower half
Index 1, least
significant nibble,
lower half
Index 2, most
significant nibble,
upper half
Index 2, least
significant nibble,
upper half
Index 2, most
significant nibble,
lower half
Index 2, least
significant nibble,
lower half
Index 64, most
significant nibble,
upper half
Index 64, least
significant nibble,
upper half
Index 64, most
significant nibble,
lower half
Index 64, least
significant nibble,
lower half
Parameter
version of GDATA,
currently 1 !!!
Startup Soundbank or
2:Multi Mode
Startup Sound Number
MIDI Channel
Program Change Mode
Device ID
DEV
Bend Range
Controller W
Controller X
Controller Y
Controller Z
Main Volume
Transpose
Master Tune
Display Timeout
LCD Contrast
Velocity Curve
Release Velocity
Pressure Curve
23
0-127
1..128
24
0-16
off/Chnl1-16
25
0-1
off/on
26
0-3
off/Ctl/SysEx/
Ctl+SysEx
27
0-1
off/on
28
0-3
1..4
29
0-16
off,Chnl1-16
30
reserved
31
0-1
closing/opening
******************************************************
******************************************************
4.) Device Inquiry
The Microwave 2 responds to the Universal Device
Inquiry message F0,7E,<channel>,06,01,F7 if <channel>
is set to 7F or if <channel> matches the specific
Device ID. The Microwave 2 will respond with the
following:
F0,7E,06,02
3E,
0E,00,
XX,YY,
VV,VV,VV,VV,
F7
Device family member codes (XX,YY):
00,00
01,00
03,00
05,00
09,00
19,00
!!! All features are coded as bitmask, so more
combinations are possible. The bitmask values:
01
Mainboard 2.0
02
XT Frontboard
04
MWPC
08
Expandable Mainboard
10
Voice Expansion
******************************************************
2.82
INFR
******************************************************
INFR
07h
Information Request
This only works for Microwave PC on Terratec EWS
Frontmodule !
The full format of a INFR Dump is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
08h
5
Typ
xx
6
EOX
F7h
Startup Multi Number
Arpeggiator Note out
Channel !!
MIDI Clock output
Parameter send
Parameter receive
Input Gain [XT only]
!!
Keyboard Send
Pedal Type
Universal Device
Header
Waldorf Electronics
Manufacturer ID
Device family code :
Microwave 2
Device family member
code, see below
Software revision,
ASCII, e.g. "2.09"
EOX
Microwave 2
Microwave 2 with XT
Mainboard (has Delay
Effects !)
Microwave XT
Microwave PC on
Terratec EWS
Frontmodule
MW2/XT with
expandable
Mainboard, 10 Voices
!!!
Expanded MW2/XT, 30
Voices !!!
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here INFR
Typ of information
End of SysEx