Herunterladen Inhalt Inhalt Diese Seite drucken

Waldorf MicroWave II Bedienungsanleitung Seite 113

Vorschau ausblenden Andere Handbücher für MicroWave II:
Inhaltsverzeichnis

Werbung

HH LL
Location
----------------------------------------------------
00 00 .. 00 7F
Control Table of Wavetables 001..128
----------------------------------------------------
Note that only Wavetables 96 to 128 are User
Wavetables, an attempt to overwrite a wavetable
outside this range will fail.
The full format of a WAVD Dump is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
13h
5
HH
see above Location
6
LL
see above Location
7-262
WCTDATA see 3.5
263
XSUM
(HH+LL+WCTDATA)&7Fh Checksum
264
EOX
F7h
------------------------------------------------------
******************************************************
2.51 GLBR
******************************************************
WCTR
04h
Global Parameter Request
Upon reception of a valid Global Parameter request,
the MW2 will dump the Global Parameters. No location
is given.
The full format of a GLBR Request is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
04h
7
XSUM
0
8
EOX
F7h
------------------------------------------------------
******************************************************
2.52 GLBD
******************************************************
GLBD
14h
Global Parameter Dump
A Global Parameter dump is used to transfer Global
Parameter date from and to the Microwave 2.
The full format of a GLBD Dump is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
14h
5-36
GDATA
see 3.6
37
XSUM
GDATA&7Fh
38
EOX
F7h
------------------------------------------------------
******************************************************
2.53 GLBP
******************************************************
GLBP
24h
Global Parameter Change
Upon reception of a valid Global Parameter Change
dump, the specified parameter will change its value
immediately according to the given value.
Bedienhandbuch MicroWave II • MicroWave XT • XTk
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here WCTD (Wavetable
Dump)
Wave control table
End of SysEx
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here GLBR (Global
Parameter request)
Checksum
End of SysEx
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here GLBD (Global
Parameter Dump)
Global Parameter
Data
Checksum
End of SysEx
See 3.6 for a detailed list of parameters and indices.
The actual Format is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
24h
5
PP
see above Parameter index
6
XX
see 3.1
7
EOX
F7h
------------------------------------------------------
Note that the checksum is omitted here.
******************************************************
2.61 DISR
******************************************************
DISR
05h
Display Request
Upon reception of a valid Display Request request, the
MW2 will dump the contents of the LCD. No location is
given.
The full format of a DISR Request is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
05h
7
XSUM
0
8
EOX
F7h
------------------------------------------------------
******************************************************
2.62 DISD
******************************************************
DISR
15h
Display Dump
A Display Dump message is used to transfer LCD
contents from and to the Microwave 2.
The full format of a DISD Request is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
15h
5-84
LCDDATA ASCII
85
LEDDATA
86
XSUM
0
87
EOX
F7h
------------------------------------------------------
******************************************************
2.63 DISP
******************************************************
DISP
25h
LCD Parameter change
A LCD
Parameter Change is used to change a single
character in the LCD of the the Microwave 2.
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here GLBP (Global
Parameter change)
New Parameter value
End of Exclusive
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here DISR (LCD
request)
Checksum
End of SysEx
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here DISD (LCD dump)
Upper and lower row
of LCD
LEDs Bitmask:
01: MIDI
02: Column #1
04: Column #2
08: Column #3
10: Column #4
20: Column #5
40: Play
Checksum
End of SysEx
113

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Microwave xtXtk

Inhaltsverzeichnis