The full format of a DISP Dump is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
25h
5
LOC
0-79
6
CHAR
ASCII
7
XSUM
(LOC+CHAR)&7Fh
8
EOX
F7h
------------------------------------------------------
******************************************************
2.64 DISL
******************************************************
DISL
45h
LCD Recall
Upon receprion of a Display Recall message, the LCD
and the LEDs will be updated in order to discard a
possibly previously dumped LCD content.
The full format of a DISL Dump is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
45h
5
XSUM
0
6
EOX
F7h
------------------------------------------------------
******************************************************
2.71 RMTP
******************************************************
RMTP
26h
Remote Control Parameter Change
The remote control Parameter change is used to
remotely control the encoders and buttons of the
Microwave 2. Operation might still introduce bugs.
The Element to move is coded in one byte:
UU
Element
------------------------------------------------
00
Encoder #1
01
Encoder #2
02
Encoder #3
03
Encoder #4
04
Encoder #5
05
Play/Shift button
06
Soundpar #1/Store button
07
Soundpar #2/Recall button
08
Soundpar #3/Compare button
09
Multipar/Undo button
0A
Global/Utility button
0B
Power button
------------------------------------------------
Annother byte defines the movement to be simulated:
MM
Encoder
------------------------------------------------
00
encoder left turn -64
01
encoder left turn -63
2-63
encoder left by MM
64
no encoder move
65
encoder right by one
66-127
encoder right by MM
------------------------------------------------
The full format of a RMTP Dump is:
114
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here DISP (LCD
Parameter change)
Index of character
in LCD
New character
Checksum
End of SysEx
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here DISL (LCD
Recall)
Checksum
End of SysEx
(left)
(big red one)
Button
released
pressed
pressed
pressed
pressed
pressed
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
26h
5
UU
see text
6
MM
see text
7
XSUM
(UU+MM)&7Fh
8
EOX
F7h
------------------------------------------------------
******************************************************
2.81 MODR
******************************************************
MODR
07h
Mode Request
The full format of a MODR Dump is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
07h
5
EOX
F7h
------------------------------------------------------
******************************************************
2.82 MODD
******************************************************
MODD
17h
Mode Dump
The full format of a MODD Dump is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
17h
5
Mode
0-1
6
EOX
F7h
------------------------------------------------------
******************************************************
Bedienhandbuch MicroWave II • MicroWave XT • XTk
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here RMTP
Element
Simulated movement
Checksum
End of SysEx
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here MODR
End of SysEx
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here MODD
0: Sound 1:Multi
End of SysEx

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Microwave xtXtk

Inhaltsverzeichnis