179-206 IDATA
see 3.3
207-234 IDATA
see 3.3
235-262 IDATA
see 3.3
263
XSUM
(BB+NN+DATA)&7Fh Checksum
264
EOX
F7h
------------------------------------------------------
******************************************************
2.23 MULP
******************************************************
MULP
20h
Multi Parameter Change
Upon reception of a valid Multi Parameter Change dump,
the specified parameter will change its value
immediately according to the given value. In Sound
Mode, all MULP messages will be ignored. The location
is given in one byte with following conventions:
LL
Location
------------------------------------------------
20h
Multi Edit Buffer
01h..07h
Multi Mode Instrument 1..8 buffer
------------------------------------------------
The Parameter index is given in one byte:
PP
Parameter index
------------------------------------------------
00..1Fh Parameters with indices 0 to 31
------------------------------------------------
See 3.2 for a detailed list of Multi parameters and
indices, or 3.3 for a detailed list of Instrument
parameters and indices.
The actual Format is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
21h
5
LL
see above Location
7
PP
see above Parameter index
8
XX
see 3.2/3.3
9
EOX
F7h
------------------------------------------------------
******************************************************
2.31 WAVR
******************************************************
WAVR
02h
Wave Request
Upon reception of a valid wave request the MW2 will
dump the selected Wave. The location is given in two
bytes with following conventions:
HH LL
Location
------------------------------------------------
00 00 .. 00 7F
ROM Waves 000..127
01 00 .. 01 7F
ROM Waves 128..255
01 00 .. 01 2B
ROM Waves 256..299
07 68 .. 07 7F
User Waves 1000..1023
08 00 .. 08 7F
User Waves 1024..10151
09 00 .. 09 61
User Waves 1152..1249
------------------------------------------------
So the full format of a WAVR Request is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
02h
5
HH
see Text
6
LL
see Text
7
XSUM
(HH+LL)&7Fh
8
EOX
F7h
112
Instrument #6 data
Instrument #7 data
Instrument #8 data
End of SysEx
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here MULP (Sound
Parameter change)
New Parameter value
End of Exclusive
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here WAVR (Wave
request)
Location
Location
Checksum
End of SysEx
------------------------------------------------------
******************************************************
2.32 WAVD
******************************************************
WAVD
12h
Wave Dump
A wave dump is used to transfer wave data from and to
the Microwave 2. The location is given in two bytes
with following conventions:
HH LL
Location
------------------------------------------------
00 00 .. 00 7F
ROM Waves 000..127
01 00 .. 01 7F
ROM Waves 128..255
02 00 .. 02 2B
ROM Waves 256..299
07 68 .. 07 7F
User Waves 1000..1023
08 00 .. 08 7F
User Waves 1024..10151
09 00 .. 09 61
User Waves 1152..1249
------------------------------------------------
So the full format of a WAVD Dump is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
12h
5
HH
see above Location
6
LL
see above Location
7-134
WDATA
see 3.4
135
XSUM
(HH+LL+WDATA)&7Fh Checksum
136
EOX
F7h
------------------------------------------------------
******************************************************
2.41 WCTR
******************************************************
WCTR
03h
Wave Control Table Request
Upon reception of a valid wave control table request,
the MW2 will dump the selected Table. The location is
given in two bytes with following conventions:
HH LL
Location
-----------------------------------------------------
00 00 .. 00 7F
Control Table of Wavetables 001..128
-----------------------------------------------------
Note that some Wavetables are generated
algorithmically and have no control table, an attempt
to request such a table will fail.
The full format of a WCTR Request is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
03h
5
HH
see Text
6
LL
see Text
7
XSUM
(HH+LL)&7Fh
8
EOX
F7h
------------------------------------------------------
******************************************************
2.42 WCTD
******************************************************
**************
WAVD
13h
Wave ControlDump
A Control Table dump is used to transfer Wavetable
Control Table data from and to the Microwave 2. The
location is given in two bytes with following
conventions:
Bedienhandbuch MicroWave II • MicroWave XT • XTk
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here WAVD (Wave
Dump)
Wave data
End of SysEx
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here WCTR (Wavetable
request)
Location
Location
Checksum
End of SysEx