2.12 SNDD
******************************************************
SNDD
10h
Sound Dump
A sound dump is used to transfer sound data from and
to the Microwave 2. The location is given in two bytes
with following conventions:
BB NN
Location
------------------------------------------------
00 00 .. 00 7F
Locations A001..A128
01 00 .. 01 7F
Locations B001..B128
10 00
All Sounds
20 00
Sound Mode Edit Buffer
30 00 .. 30 07
Multi Instrument Edit Buffers
------------------------------------------------
So the full format of a SNDD Dump is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
10h
5
BB
see above Location
6
NN
see above Location
7-262
SDATA
see 3.1
263
XSUM
(BB+NN+SDATA)&7Fh Checksum
264
EOX
F7h
------------------------------------------------------
Or in case of All Sounds Dump:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
10h
5
BB
see above Location
6
NN
see above Location
7-65542 SDATA[256]
see 3.1
65543
XSUM
(BB+NN+SDATA)&7Fh Checksum
65544
EOX
F7h
------------------------------------------------------
******************************************************
2.13 SNDP
******************************************************
SNDP
20h
Sound Parameter Change
Upon reception of a valid Sound Parameter Change dump,
the specified parameter will change its value
immediately according to the given value. The ocation
is given in one byte with following conventions:
LL
Location
------------------------------------------------
00h
Sound Mode Edit Buffer or...
00h..07h
Multi Mode Instrument 1..8 sound
buffer
------------------------------------------------
The Parameter index is given in two bytes:
HH
PP
Parameter index
------------------------------------------------
00h 00..7Fh
Parameters with indices 0 to 127
01h 00..7Fh
Parameters with indices 0 to 127
------------------------------------------------
See 3.1 for a detailed list of parameters and indices.
So the actual Format is:
Index
Label
Value
------------------------------------------------------
Bedienhandbuch MicroWave II • MicroWave XT • XTk
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here SNDD (Sound
Dump)
Sound data
End of SysEx
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here SNDD (Sound
Dump)
256 times Sound data
from A001 to B128
End of SysEx
Description
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
20h
5
LL
see above Location
6
HH
see above Parameter index high bit
7
PP
see above Parameter index
8
XX
see 3.1
9
EOX
F7h
------------------------------------------------------
Note that the checksum is omitted here.
******************************************************
2.21 MULR
******************************************************
MULR
11h
Multi Request
Upon reception of a valid multi request the MW2 will
dump the selected Multi(s). The location is given in
two bytes with following conventions:
BB NN
Location
------------------------------------------------
00 00 .. 00 7F
Locations 001..128
10 00
All Multis
20 00
Edit Buffer
------------------------------------------------
So the full format of a MULR Dump is:
Index
Label
Value
------------------------------------------------------
-----
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
01h
5
BB
see Text
6
NN
see Text
7
XSUM
(BB+NN)&7Fh
8
EOX
F7h
------------------------------------------------------
******************************************************
2.22 MULD
******************************************************
MULD
21h
Multi Dump
A multi dump is used to transfer multi data from and
to the Microwave 2. The location is given in two bytes
with following conventions:
BB NN
Location
------------------------------------------------
00 00 .. 00 7F
Locations 001..128
10 00
All Multis
20 00
Edit Buffer
------------------------------------------------
So the full format of a MULD Dump is:
Index
Label
Value
------------------------------------------------------
0
EXC
F0h
1
IDW
3Eh
2
IDE
0Eh
3
DEV
4
IDM
11h
5
BB
see above
6
NN
see above
7-38
MDATA
see 3.2
39-66
IDATA
see 3.3
67-94
IDATA
see 3.3
95-122
IDATA
see 3.3
123-150 IDATA
see 3.3
151-178 IDATA
see 3.3
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here SNDP (Sound
Parameter change)
New Parameter value
End of Exclusive
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here MULR (Multi
request)
Location
Location
Checksum
End of SysEx
Description
Marks Start of SysEx
Waldorf Electronics
GmbH ID
Microwave 2 ID
Device ID
here MULD (Multi
Dump)
Location
Location
Multi data
Instrument #1 data
Instrument #2 data
Instrument #3 data
Instrument #4 data
Instrument #5 data
111